SC 10 T mehrspr_neu
GB
Operating display indications
LED color
Indicator with steady light
Red
X
Red
Orange
Orange
Green
Green
X
No indication
Note:
For safety reasons, the controller switches off the heater after an operating period of 6 hours. Resetting is
only possible with the operating switch.
Setting the sauna temperature
When the main switch (No. 1) is actuated, the heater
heats up the sauna to the temperature set with the
regulator knob (No. 3).
Exception: This does not happen when the electronic
fine atomizer is inside the sauna. In this case the
temperature is heated to a maximum of 60°. For an
exact description please see the installation and
operating instructions of the evaporator unit.
12
13.01.2006
9:13 Uhr
Indicator with flashing light
X
X
X
X
Seite 12
Function
Oven is heating
Temperature cut-out in cabin
is defective
AV50 fine atomizer (where
available) is in the cabin and
the HC 10-D controller is not
switched on
SC10-T and HC10-D are
switched on. BIO-Mat is active
Sensor is broken
Oven is not heating because
the temperature has been
reached. Time pre-set is active
6 hours safety cut-out
Setting the time (timer function)
The time remaining before the heater is switched on
can be set with button + (No. 6) and button - (No. 4).
Signals are issued by a total of 12 LEDs (each LED
represents exactly one hour). The selected time can
be changed at any time by pressing the buttons „+"
or „-". If you keep on pressing the button - until the
display is at 0 again, the heater will switch on
immediately.
The timer function can also be used to arrange a
break in operation. To do so, keep pressing the
button + until the required break period (time
remaining until the heater switches on again) is
selected. Heating starts up again when the set period
has elapsed.