Hoover H-FREE 500 Hydro Plus Manuel D'utilisation page 10

Masquer les pouces Voir aussi pour H-FREE 500 Hydro Plus:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
VACUUM AND INTEGRATED WASH FUNCTION
IMPORTANT: The integrated wash function should only be used on Hard Floors and Parquet.
This cleaner has a Hybrid Care roller at the front of the nozzle, and a 360° Hydro roller at the rear of the nozzle to allow
vacuuming and wash of hard floors and parquet. [3a]
Before using the double function, it is important to fully wet the 360° Hydro roller.
1. Detach the 360° Hydro roller release flap. It is positioned on the lateral side of the nozzle. [3b]
2. Hold the 360° Hydro roller release flap and remove it.
3. Remove the sealing cap, and using the sealing cap as a measuring cup, fill with the provided concentrated detergent
and pour into the 360° Hydro roller. [3c, 3d]
4. Fill in the 360° Hydro roller with water without filling to the brim. [3e]
5. Then re-fit the sealing cap.
6. Insert the 360° Hydro roller into the Pre-wet container, pour water into the Pre-wet container without filling to the brim.
Keep the 360° Hydro roller within the container for around 30 seconds ensuring all areas are wet then remove it. [3f, 3g,
3h]
7. Re-fit the 360° Hydro roller into the nozzle to its original position and close the release flap to the nozzle. [3i]
IMPORTANT: Do not use the 360° Hydro roller on carpets when it's wet.
IMPORTANT: This is a dry DC stick, do not vacuum any water or liquids.
NOTE: It is possible to use alternative gentle cleaning detergents but do not use disinfectant.
NOTE: It is recommended to refill the tank and ensure the 360° Hydro roller is fully wet after covering an area of around
40m
2
for optimal cleaning of surfaces.
NOTE: When you need to refill the water tank and the 360° Hydro roller is already dirty, it is recommended to wash it in
lukewarm water with a gentle detergent by squeezing it.
IMPORTANT: It is recommended to wash the 360° Hydro roller after every use and to dry in an upright position for at
least 24 hours. [4]
IMPORTANT: Do not leave the wet 360° Hydro roller in the nozzle.
VACUUM FUNCTION
IMPORTANT: The vacuum function should only be used when the Hydro roller is completely dry.
This cleaner has a Hybrid Care roller on the front side of the nozzle and allows pick up of dust and debris from hard floors,
parquet and carpets. [4f]
Before using your product on carpet, remove the 360° Hydro roller from the nozzle, empty the contents and leave to dry
for 24Hrs before refitting. [4a, 4b, 4c, 4d, 4e]
Alternatively, if you do not want to wait, simply remove the wet 360° Hydro roller and vacuum your carpet. [4a]
USING YOUR CLEANER
USER INTERFACE
There are 4 working modes.
• STANDARD MODE: When you press ON-OFF button, the cleaner is ready to clean thoroughly with the main motorized
nozzle. [6a]
• TURBO MODE: Press the Turbo button to fully power the product for hard cleaning tasks. [6b]
• SILENT MODE: Press the Silent Mode button to clean thoroughly at the lowest noise level of this product. [6c]
• AUTO MODE: When you remove the nozzle or the tube, the product automatically adapts to lower power for above
floor cleaning, with non-motorized tools.
NOTE: When in this mode, if you require higher power, press the Turbo Button: once to get extra power or twice to get full
power. If you want to go back to Auto Mode, press Silent Button.
BRUSH BAR STATUS
The brush bar status LED on the nozzle will stay illuminated white during all floor cleaning modes and will turn red if the
safety protection system is activated. [17]
* Certain Models Only
4
GB

Publicité

Table des Matières
loading

Table des Matières