Installation

• Supplied components
The instrument is always supplied inside the specific carrying case with these accessories:
batteries, adaptor 5V with USB cable, standard 0 oxygen, paper tissues, screwdriver, beacker, multilingual
user manual and test report. Contact your local distributor to be updated on the correct composition of the
sales kit and spare parts.
• Start-up
The device leaves the factory ready to be used by the user.
Batteries are included.
• Connection of the power supply
in addition to batteries, the instrument can be powered through electricity grid;
check that the electrical standards of the line on which the instrumentation is to be installed comply
with the voltage and operating frequency of the instrument;
use the original power supply only;
connect the power supply to the USB cable and the other end of the cable (Micro USB) to the Micro
USB port located on the front of the instrument;
Connect the power supply to an electric socket easy to reach.
ATTENTION - Danger of death or serious injury from electric shock.
Contact with live components can lead to injury or death.
Use the adapter supplied only.
Do not put the power supply in contact with liquids nor in a condensing environment. Avoid thermal shock.
All electrical cables and connections must be kept away from moisture or liquids.
Check that the cables and plugs are not damaged, otherwise replace them.
During use, do not cover the power supply and/or do not place it inside containers.
The electricity supply can be originated from the power grid and from the USB port of a PC too.
If the instrument is powered by PC, the icon indicating the battery status disappears from the display
Opening the DataLink+ software, on the display it is shown this icon
• Power on, date and time update, power off
Turn on the system by pressing the button
appears:
Model and firmware of the instrument.
Settings relating to the most important parameters and possible information about the DHS sensor.
On first use, and after each battery replacement, the instrument during the start-up phase will request the
updating of the date and time.
Using the directional keys, update the year and confirm with the key
Carry out the same operation with the month and day, and subsequently with hours and minutes.
The instrument will enter measure mode in the last parameter used.
To switch off the instrument, press the key
UM Serie Oxy70Vio EN rev.0 28.05.2020
.
. The display initially activates all segments and then
in measure mode.
9
.
EN
.