Display during Operation
Operating mode
1:n = impulse
multiplication
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Mem = Memory alarm
Paragraph 5 – Proportional to External Impulses (division)
Programming
PROG
Configuration
Pump Funtions
-
+
Pump
Functions
Divide (n:1)
Divide (n:1)
n
4
-
Display during Operation
Operating mode
1:n = impulse
multiplication
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Paragraph 6 – Proportional to External Impulses (batch dosage)
Programming
PROG
Configuration
Pump Funtions
-
+
Pump Functions
Batch mode (1:c)
Batch mode (1:c)
Q.ty
10.0ml
-
Batch mode (1:c)
Time
10s
-
Batch mode (1:c)
Memory
Off
-
EM00136061
FLOW
Memory
sensor
function
status
status
1:n
F
M
1
F
M
F
M
Lev
Stop
0
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
The pump doses in proportion to an external signal (i.e.: impulse launch
counter). At every "n" signals, the pump makes a strike. You can set the
value of "n" during programming. By programming the value of "n" you set
the maximum dosage %. This value can be modified during operation, by
pressing the
-
+
FLOW
sensor
status
N:1
F
4
F
F
Lev
Stop
P100%
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
The pump doses in proportion to an external signal (i.e.: impulse
launch counter). In this case, it is possible to set the quantity to be
dosed in ml and the time within which to complete dosage.
Dosage can be started manually by pressing the
using a remote control. The
be reset by pressing the
-
+
-
The quantity to be dosed can be modified during operation, by
+
pressing the
-
+
or the
Programmed
value of n
Current dosage value
Displays stroke
countdown
keys at the same time to increase the flow, or the
keys to decrease it.
Programmed
value of n
Current dosage value
Maximum dosage
percentage
key again.
keys to decrease i.
rev. 2.1
Display during Setting (MODE key)
Displays programmed
timeout
Timeout
0s
Current dosage value

Displays the value of n. This
can be modified by pressing
the + or – keys at the same
time
Operation
Display during Setting (MODE key)
Operating mode
n:1
6
6
P100%
Effective
Current dosage value
value of "n"

The dosage % can be modified
by pressing the + or – keys at
the same time
Operation
key interrupts dosage, which can
key, or started again by pressing the
keys at the same time to increase the flow,
n
1
Programmed value

Value of n
key, or by
5