Figure 3: Connecting one 12XTi to the LA4 / LA4X amp channel #1
!
To ensure both high performance and safety, L-ACOUSTICS
high-quality, fully insulated speaker cables made of stranded copper wire.
In order to preserve a high damping factor it is desirable to keep loudspeaker cables as short as
possible and with a gauge offering low resistance per unit length.
IMPORTANT
The following table provides information regarding the recommended length versus wire cross-section.
Table 1: Maximum cable length versus conductor cross-section for Damping Factor > 20
2
mm
2.5
4
6
10
According to the calculation in Table 1, one SP25 cable (4 mm², 25 m) can be used to power one 12XTi (8 Ω load) with
a damping factor still greater than 20.
12XTI_UM_ML_1-1
Cross-section
SWG
AWG
15
13
13
11
11
9
9
7
w w w . l - a c o u s t i c s . c o m
SP.7, SP10, or SP25
®
recommends the exclusive use of
Maximum length for one 12XTi (8 Ω load)
m
30
50
74
120
ft
100
160
240
390