USING YOUR DYSON AM10 HUMIDIFIER
Please read the 'Important Safety Instructions' in this Dyson
Operating Manual before proceeding.
Introduction
This is a cool mist, ultrasonic humidifier. Moist air is directed
into the room from the loop amplifier.
Water passes over a UV-C emitter to ensure that it is 99.9%
bacteria-free before misting commences.
Location
Always place the Dyson AM10 humidifier on a firm, flat,
level surface.
Do not place the Dyson AM10 humidifier on a rug, carpet,
wooden flooring, or any other surface that may be damaged by
exposure to water or moisture.
It is recommended that a waterproof mat or pad is placed
under the Dyson AM10 humidifer.
Do not place the Dyson AM10 humidifer underneath
overhanging surfaces.
Do not place the Dyson AM10 humidifer in an area where it is
accessible to children.
Store the Dyson AM10 humidifer indoors. Do not use or store
it below 5°C (41°F). Ensure that it is at room temperature
before operating.
For the best performance, place on the floor, in the corner of
the room, at least 1m from any wall and facing into the centre
of the room.
Operation
All parts must be securely fitted before use.
Do not use the Dyson AM10 humidifer unless it has been
cleaned according to instructions.
In humidifier mode do not use without water in the tank.
Do not lubricate any part of the Dyson AM10 humidifer.
When switched on, a small blue LED on the back of the Dyson
AM10 humidifer lights up to show that power is being received
by AM10. (Note: It does not mean that AM10 itself is operating.)
Once the water treatment cycle completes, the Dyson
AM10 humidifer is ready to begin humidification.
Setting humidity level
On first use, the display will show '70%', which is the highest
relative humidity setting. The fan will run on lowest airspeed,
'01'. For each use after this the Dyson AM10 humidifer will
remember the last target humidity level and airflow speed set.
The Dyson AM10 humidifier will not operate unless the target
humidity setting is above the current room humidity level.
The Dyson AM10 humidifer will automatically adjust to avoid
excessive humidity.
Mist will be visible only in certain conditions (impacted by light,
background colour, etc.) or at the lowest settings.
Automatic mode
Press the AUTO button on the remote. This is the recommended
mode of operation.
The Dyson AM10 humidifer selects a comfortable humidity
for the room, based on environmental factors such as current
humidity level and air temperature.
When the room reaches the appropriate humidity level the
Dyson AM10 humidifer will switch itself 'ON' or 'OFF' as
necessary to maintain that level. The fan will remain running
when the target humidity has been reached.
Manual mode
Select the desired humidity level (from 30% to 70%). When
the room reaches the target humidity level the Dyson
AM10 humidifer will switch itself 'ON' or 'OFF' as necessary to
maintain that level. The fan will remain running when the target
humidity has been reached.
28
Fan mode
The fan mode button on the remote control turns the humidifier
mode 'OFF'. Control the fan mode using the airflow and
timer buttons.
No water is needed for the fan mode.
Control without remote
Press the power button on the Dyson AM10 humidifer to turn
ON/OFF.
Press and hold the power button on the Dyson AM10 humidifer
to adjust the humidity.
Fan mode and the sleep timer cannot be operated without the
remote control.
The air speed setting automatically sets to '05'.
Refilling
Filtered or distilled tap water is recommended to avoid white
dust in hard water areas.
When refilling, empty the tank completely (preferably washing
and drying it), then refill – this keeps the water fresh.
With a full tank of clean, cool tap water (2.84 litres) the Dyson
AM10 humidifer will run for at least 10 hours, depending on the
target humidity setting and other environmental conditions. Do
not add anything to the water (such as scents, oils etc).
Cleaning the base
Small water spillages may occur. While the amount of water
in the trough is not significant enough to damage the Dyson
AM10 humidifer, significant care should be taken when
emptying it. Ensure that water does not enter through the inlets.
If some water does pass through the inlets, dry the exterior with
a cloth and continue to use as normal.
Cleaning the tank
Pour in the recommended acid citric solution. Replace the cap
and shake tank for 30 seconds. Then leave to stand. After
15 minutes, empty the tank. Rinse and wipe over all surfaces.
Repeat if necessary.
Storage
When not in use, unplug from the mains electricity supply.
Store the Dyson AM10 humidifier in a dry location and arrange
the cable away from traffic areas so that it will not be tripped
over or damaged.
Clean the Dyson AM10 humidifer and tank as instructed before
storing and before re-use.
Battery replacement
CAUTION
Unscrew the battery compartment on the remote control.
Loosen the base and pull to remove the battery.
Do not install backwards or short circuit the batteries.
Do not attempt to dismantle or charge the batteries. Keep away
from fire.
Always replace the screw in the remote control.
Follow battery manufacturers' instructions when installing new
batteries (battery type CR 2032).
Limited functionality is available without the remote control (see
'Control without the remote').
Automatic cut-out
If the appliance is tilted by over 5° the display will show a 'tilted'
graphic. If after 15 minutes the Dyson AM10 humidifer is not
levelled it will switch 'OFF'.
If the Dyson AM10 humidifer has been tilted make sure it is
level and clear up any spillage.