Elica Comfort Asti Série Instructions D'installation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Venting Outside Through the Roof
1. Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent.
A
A. Cutout
B. 6¼" (15.9 cm)*
C. 7¾" (19.7 cm) centerline to cabinet front
D. Centerline
*NOTE: For 12" (30.5 cm) high cabinets a 6¼" deep x 8" wide
(14.6 cm x 20.3 cm) rectangular opening in the cabinet top is
required for damper transition clearance.
Venting Outside Through the Wall
1. Install the 6" (15.2 cm) vent transition to the top of the range
hood liner using two 3.5 x 9.5 mm screws. Assemble the vent
duct that you will use over the 6" (15.2 cm) vent transition.
2. Measure from the bottom of the range hood liner to the
horizontal centerline of the vent opening (A)
B
A
C
3. Remove the vent duct from the range hood liner.
Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet.
4. Mark the cutout as shown. Use a saber saw or keyhole saw to
cut a round opening through the back of the cabinet and the
exterior wall for the vent. Go to Step 3.
B*
C
D
A. Measurement A
B. Horizontal centerline of vent opening
C. Range hood liner
A
C
B
Non-Vented (recirculating) Installation Through the
Soffit/Cabinet
A
G
B
D
F
E
A. Ceiling
B. Vent cover
C. Soffit
D. 6" (15.2 cm) vent
E. Range hood
1. Measure and mark the centerline of the cabinet to the soffit
above.
2. Measure from the bottom of the cabinet to the centerline of
the where the vent will come through the soffit. Mark the
location and use a saber saw or keyhole saw to cut a 5¾"
(14.6 cm) hole for the vent cover.
A
*NOTE: For 12" (30.5 cm) high cabinets a 6¼" deep x 8" wide
(14.6 cm x 20.3 cm) rectangular opening in the cabinet top is
required for damper transition clearance.
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
8
A. Measurement A
B. Centerline
C. 6¼" (15.9 cm) round
cutout
G
F
I
H
F. Cabinet
G.Wall
H. 12" (30.5 cm) min. cabinet height
I. 17" (43.2 cm) min. vent cover height
B
A. Vent cover
B. Centerline
A
B
C
D
E

Publicité