DEVYL D ie FF
fi x it to the gas collector
- position the cable gland with the spark plug cable in its seat on the air
tank
- reconnect the spark plug cable
- refi t the combustion chamber cover and the air tank cover
- to access the circuit board, open the instrument panel, following the in-
structions contained in paragraph 6.1
- on the control board (fi g. 3):
- if converting from methane gas to LPG, insert the jumper in position
JP1
- if converting from LPG to methane gas, remove the jumper from posi-
tion JP1
CN5
P1
1
JP1
CN7
11
- reposition the components previously removed
- reconnect the appliance to the mains and turn on the gas valve (with the
boiler in operation, check the gas supply circuit seals).
Once conversion is complete, set the appliance as detailed in
the relevant section of this manual and attach the new data ID
plate contained in the kit.

3.10 Setting the appliance

The boiler has already been factory set by the manufacturer.
However, should it need to be readjusted, for example after non-scheduled
maintenance, replacing the gas valve or gas conversion, proceed as de-
scribed below.
Adjustments to maximum power must be performed in the indi-
cated sequence and only by qualifi ed technicians.
- Remove the casing by loosening the screws holding it in place(A) (see
section 6 "Removing the casing").
- Loosen the pressure tapping point screw (1) located downstream of the
gas valve by approximately two turns and connect a pressure gauge
there.
- Disconnect the compensation inlet (5) from the gas valve.
- Remove the protective cap (2).
- Turn a water tap on fully, bring the temperature selector to the maximum
and connect the boiler to a power supply.
1
26
JP4
P2
T1
fi g. 3
5
2
3
4
Setting to the maximum value:
- Screw the nut (3) fully until obtaining the gas pressure shown in the table.
Maximum gas pressure at nozzles
G20
11
G30
D ie FF
G31
G20
13
G30
D ie FF
G31
G20
17
G30
D ie FF
G31
Setting to the minimum value:
- disconnect one of the two electrical cables from the coil
- screw or unscrew the hex head socket screw (4) to adjust the minimum
until obtaining the gas pressure value shown in the table
- refi t the protective cap (2).
Minimum gas pressure at nozzles
G20
11
G30
D ie FF
G31
G20
13
G30
D ie FF
G31
G20
17
G30
D ie FF
G31
- Reconnect the compensation inlet to the gas valve (5).
- Disconnect the pressure gauge and retighten the pressure tapping point
screw (1).
Please remember that for operation with LPG, a gas pressure regu-
lator at the appliance power supply is required, set to 28-30 mbar if
operating with butane and 37 mbar for propane.
10,40
mbar
106,05
mm. H
28,00
mbar
285,52
mm. H
36,00
mbar
367,10
mm. H
11,80
mbar
120,33
mm. H
27,80
mbar
283,48
mm. H
35,80
mbar
365,06
mm. H
11,30
mbar
115,23
mm. H
28,00
mbar
285,52
mm. H
36,00
mbar
367,10
mm. H
1,20
mbar
12,24
mm. H
3,00
mbar
30,59
mm. H
3,90
mbar
39,77
mm. H
1,50
mbar
15,30
mm. H
3,30
mbar
33,65
mm. H
4,30
mbar
43,85
mm. H
1,60
mbar
16,32
mm. H
3,60
mbar
36,71
mm. H
4,80
mbar
48,95
mm. H
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2
O
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Devyl 13 d ie ffDevyl 17 d ie ff

Table des Matières