Changing the battery
This battery can be switched between 2 charge levels (4 Ah / 6 Ah).
-
4.0 Ah (72 Wh) --> better for the battery, extending its total life by about 3 times
-
6.0 Ah (108 Wh) --> long operating time per battery charge
The battery is supplied with 4.0 Ah (72 Wh).
To switch between 4.0 Ah and 6.0 Ah, proceed as follows:
Important! Read the instructions through completely before changing the battery setting!
1.
Hold the button for the battery charge level indicator (A) down for about 6 seconds until the battery on the display
(B) begins to count from 1 to 9.
2.
- To switch from 4 Ah to 6 Ah, press the button (A) briefl y again when the number 6 is displayed. The count then
continues as normal to 9.
- To switch from 6 Ah to 4 Ah, press the button (A) briefl y again when the number 4 is displayed. The count then
continues as normal to 9.
3.
Once the display (B) has reached 9, the new setting "6Ah" or "4Ah" will be indicated for about 2 seconds.
The battery is now switched and ready for use.
The battery can only be switched if the number 4 or 6 is pressed. Other numbers do not have any signifi cance.
This process is essential in order to avoid switching over inadvertently.
Important! According to special provision 188, the lithium-ion battery must always be set to 4 Ah (72 Wh) before
it can be shipped or transported! Faulty lithium-ion batteries must never be shipped in the ordinary mail! Ple-
ase contact iSC GmbH, Eschenstraße 6, 94405 Landau/Isar (Germany) for this.
www.isc-gmbh.info
Battery charge level indicator
Press the battery charge level indicator button (A) briefl y. The display (B) for the battery charge level indicator initially dis-
plays the charge status in % and then the current set charge level consecutively for 2 seconds each.
Important!
The charge status adjusts automatically after a switch to 4 Ah or 6 Ah and can diff er from the previous setting. If the battery
has a charge status of 100 % when set to 4.0 Ah, for instance, and is then switched to 6.0 Ah, the charge status will fall to
signifi cantly less than 100 %. You will need to recharge the battery.
Error codes
Code
F01
The battery is too hot (e.g. due to direct
sunlight)
F02
The battery is too cold
F03
The battery is overloaded.
F04
The battery is defective
F05
The battery is partially fully discharged
Anl_Power_X_Change_4_to_6_SPK7.indb 3
Anl_Power_X_Change_4_to_6_SPK7.indb 3
GB
The corresponding safety information / instructions can be
found in the safety information and original operating instruc-
tions issued for the equipment. Warning! Read all the safety
information and instructions carefully!
A
Description
A - Button for battery charge level indicator
B - Display for battery charge level indicator
B
Cause
Store it at room temperature (approx. 20° C) for one
day.
Store it at room temperature (approx. 20° C) for one
day.
Remove the battery from the equipment and try it
again. No change: see F01
A defective battery is not allowed to be used any more.
Recharge the battery.