CYCLE FUNCTIONS
SETTINGS
TIME
TEMPERATURE
PRE
WATER INLETS
WASH
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
WATER INLETS
WASH
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
RINSE
WATER INLETS
1
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
RINSE
WATER INLETS
2
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
RINSE
WATER INLETS
3
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
RINSE
WATER INLETS
4
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
1 min.
TIME
TEMPERATURE
RINSE
WATER INLETS
5
WATER LEVEL
DRUM ACTION
COOLING
FINAL SPIN
DRAINING ACTION
5 min.
DISTRIBUTION
DRUM ACTION
E 1 =
SOLENOID VALVE
E 2 =
SOLENOID VALVE
E 3 =
SOLENOID VALVE
E 4 =
SOLENOID VALVE
E 5 =
SOLENOID VALVE
ENGLISH
temperature
45/90°C
CYCLE 1
4 minutes
45°C
E3 , E5
LOW
STRONG
NONE
Drain and
500rpm spin
5 minutes
90°C
E2 , E3
LOW
STRONG
Up to 65°C with E5
NONE
2 minutes
Only cold water
E5
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E5
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E4
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E4
HIGH
STRONG
NONE
Drain and
500rpm spin
3 minutes
Only cold water
E4 , E1
HIGH
STRONG
NONE
Drain and
500rpm spin
STRONG
HARD WATERDISPENSER
HOT WATER DISPENSER
HOT WATER TUB
HARD WATERTUB
HARD WATERDISPENSER
57
CYCLE FUNCTIONS
SETTINGS
TIME
TEMPERATURE
PRE
WATER INLETS
WASH
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
WATER INLETS
WASH
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
RINSE
WATER INLETS
1
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
RINSE
WATER INLETS
2
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
RINSE
WATER INLETS
3
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
RINSE
WATER INLETS
4
WATER LEVEL
DRUM ACTION
COOLING
SPIN
DRAINING ACTION
TIME
TEMPERATURE
RINSE
WATER INLETS
5
WATER LEVEL
DRUM ACTION
COOLING
FINAL SPIN
DRAINING ACTION
DISTRIBUTION
DRUM ACTION
temperature
30/60°C
CYCLE 2
4 minutes
30°C
E3 , E5
LOW
STRONG
NONE
NON
500rpm spin
5 minutes
60°C
E2 , E3 , E5
LOW
STRONG
Up to 40°C with E5
NONE
2 minutes
Only cold water
E5
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E5
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E4
HIGH
STRONG
NONE
Drain and
500rpm spin
2 minutes
Only cold water
E4
HIGH
STRONG
NONE
Drain and
500rpm spin
3 minutes
Only cold water
E4 , E1
HIGH
STRONG
NONE
Drain and
500rpm spin
STRONG

Publicité