Maintenance instructions
Please regularly check and tighten all screwed connections. Loose connections may cause a safety risk. Periodically remove dust and dirt from the
outside of the system and make sure that there is no damage or cracking. Check all connections, cables and plugs to ensure that they are functio-
ning correctly; also check the mounting points.
Repairs
To avoid any malfunction, all DESKLINE® repairs may only be carried out by authorised LINAK workshops or service personnel, as special tools must
be used and seals must be adjusted. Solution for addressing possible simple faults can be found in the "Troubleshooting" section.
Caution! Changes in the installation and application of LINAK products/systems may affect the operation
and lifetime of the product. The products must not be opened by unauthorised persons.
If a DESKLINE® product is opened, there is a risk of subsequent malfunction.
Troubleshooting
Error
Desk does not move
Desk moves down only
slowly
Desk moves only slowly
Desk moves briefly on
one side only and then
stops
Instructions for resetting the desk
If the desk requires a reset, proceed as follows:
Press the "down" key. The legs will move into the lower position. Release the button briefly and then press and hold the down button for at least
6 seconds after all legs have reached the lower position. With certain types of fault, this must be done twice in succession. Now the desk has
been reset.
Technical data
• Electrically height-adjustable desk with an adjustment range of 70 cm - 120 cm
• Stepless height adjustment - each lifting column is equipped with a motor
• High-quality actuator system from Danish manufacturer LINAK
• Maximum load 70 kg
• Speed 38 mm/s
• Low noise level < 50 dBA
• System PVC-free
• Output 140 watts
• Standby power consumption 0.1 Watt
• Simple "Plug and Play" assembly
• Top frame can be mounted without tools
04/2020
Cause
No power supply
Connection to the drives /
side parts missing or loose
No connection to the
control panel
Maximum lifting force
exceeded
Maximum activation period
exceeded
Drive faulty
Control unit faulty
Control panel faulty
Control unit must be reset
Maximum lifting force
exceeded
Connection to the drives /
side parts missing or loose
Drive faulty
Remedy
Plug in the power cable or check the connection if necessary
Check plug connection of the motor cables on the control unit and on the drives;
plug in if necessary.
Check plug connection on the control unit
Reduce weight
Control system is reactivated after 3 minutes
Caution! The maximum operation time of 2 minutes is only available again after a
rest period of at least 18 minutes
Contact customer service
Contact customer service
Contact customer service
See "Reset instructions"
Reduce weight
Check plug connection of the motor cables on the control unit and on the drives;
plug in if necessary.
Contact customer service