Plages d'entrée P 29001 P2/0x (réglage d'origine : plage 1)
N°
Plage d'entrée
bipolaire
1
–100 ... 100 V
2
–80 ... 80 V
3
–60 ... 60 V
4
–50 ... 50 V
5
–30 ... 30 V
6
–20 ... 20 V
7
–10 ... 10 V
8
–5 ... 5 V
9
–300 ... 300 mV
10 –200 ... 200 mV
11 –150 ... 150 mV
12 –120 ... 120 mV
13 –100 ... 100 mV
14 –90 ... 90 mV
15 –60 ... 60 mV
16 –30 ... 30 mV
Commu-
tateur
unipolaire
S1 : 1 ... 4
0 ... 100 V
0000
0 ... 80 V
0010
0 ... 60 V
0100
0 ... 50 V
0110
0 ... 30 V
1000
0 ... 20 V
1010
0 ... 10 V
1100
0 ... 5 V
1110
0 ... 300 mV
0001
0 ... 200 mV
0011
0 ... 150 mV
0101
0 ... 120 mV
0111
0 ... 100 mV
1001
0 ... 90 mV
1011
0 ... 60 mV
1101
0 ... 30 mV
1111
Plages d'entrée
Résistance
Bornes
d'entrée
d'entrée
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
400 kΩ
5.3 / 6.3
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
10 kΩ
5.2 / 6.2
97