that will interfere with the flow of air. The air compressor
head and shroud are designed to allow for proper cooling.
If humidity is high, an air filter can be installed on the air
outlet adapter to remove excessive moisture. Follow the
instructions packaged with the air filter for proper
installation.
Place the air compressor on a flat surface so that it is
resting securely on the rubber feet.

OPERATING TEMPERATURE

The operating temperature of this compressor is between
0°C and 40°C (32°F and 104°F).
CAUTION
Never operate the compressor in the temperatures below
0°C (32°F) and above 40°C (104°F).
Please see the chart below for the MINIMUM extension cord gauge requirements:
Amp Rating Range (120 V)
0 - 5 A
5 - 8 A
8 - 12 A
12 - 15 A
15 - 20 A
Piping
Plastic or PVC pipe is not designed for use with
compressed air. Regardless of its indicated pressure
rating, plastic pipe can burst from air pressure. Use only
metal pipe for air distribution lines. If a pipe line is
necessary, use pipe that is the same size, or larger than,
the air tank outlet. Piping that is too small will restrict the
flow of air. If piping is over 100 feet long, use the next
larger size. Bury underground lines below the frost line
and avoid pockets where condensation can gather and
freeze. Apply pressure before underground lines are
covered to make sure all pipe joints are free of leaks.
Grounding Instruction
WARNING: Risk of electric shock! In the event of a short
circuit, grounding reduces the risk of shock by providing
an escape wire for the electric current. This air
compressor must be properly grounded.
The air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug. The
plug must be used with an outlet that has been installed
and grounded in accordance with all local codes and
ordinances. The outlet must have the same configuration
as the plug. DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use. Do not use if
there are signs of damage.
DANGER:
Improper grounding can result in electrical shock. Do not
modify the plug that has been provided. If it does not fit
the available outlet, the correct outlet should be installed
by a qualified electrician.

LUBRICATION

This air compressor is equipped with an Oil-Less pump
designed for durability and no maintenance.

Extension Cords

To avoid voltage drop, power loss, and overheating of the
motor, use extra air hose instead of an extension cord.
Low voltage can cause damage to the motor.
If an extension cord must be used:
• Use only an approved 3-wire extension cord that has a
3- blade grounding plug and a 3- slot receptacle that
will accept the plug on the air compressor.
• Make sure the extension cord is in good condition.
Total Length of Cord in Meter
10 m
15 m
25 ft.
50 ft.
16
16
16
16
14
14
12
12
10
10

OPERATING PROCEDURES

Daily Start-up Checklist
INSTALLING HOSES
Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose
whip. Losing control of the hose may result in
personal injury and property damage.
1. Before attaching air hose or accessories, make sure
2. Attach hose and accessories. Too much air pressure
3. Turn the pressure switch lever to "ON/AUTO" and
4. Open the regulator by turning it clockwise. Adjust the
5. Always operate the air compressor in well-ventilated
20 m
30 m
75 ft.
100 ft.
16
14
14
12
12
10
10
10
10
WARNING
the pressure switch lever is set to "OFF" and the air
regulator or shut-off valve is closed.
causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air tools
and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.
allow tank pressure to build. Motor will stop when tank
pressure reaches "cut-out" pressure.
regulator to the correct pressure setting. Your
compressor is ready for use.
areas; free of gasoline or other solvent vapors. Do not
operate the compressor near the spray area.
50 m
60 m
150 ft.
200 ft.
12
12
10
Not Recommended