These guidelines contain instructions for fitting wood-
burning stoves on the Scan-Line rotating base. Please
read these instructions thoroughly before positioning
the rotating base on the floor, so as to make sure that
you complete the installation process correctly.
The rotating base makes it possible to turn the stove
face in the direction of your choice. Depending on the
fitting option chosen, the stove can be turned steples-
sly through 120º or 180º. If the stove is installed free-
standing and away from combustible material, 360º
free rotation is also an option.
NB: Direct supply of combustion air through the floor
is not possible when the stove is positioned on a rota-
ting base.
The rotating base is designed for the Scan-Line range.
Safety distance
Do not place any combustible material, furniture or
fittings within the safety distance indicated. Please
note that the safety distance varies according to the
installation option chosen and the angle of rotation
applied. Place the rotating base on the floor and check
the safety distance when the turning plate is rotated.

Floor plate

Remember to take the rotation of the stove into
account when calculating the size of the floor plate –
refer to the instructions for the use of your stove. No
matter what the type of flooring, the surface must be
flat and level.

Safety regulations

The owner is personally responsible for complying
with the obligatory safety requirements, and for
ensuring that the installation is checked by a respon-
sible inspector. Please pay special attention to the fact
that strong heat is radiated through the glass door. If
combustible material is placed closer to the stove than
the safety distance stated, this may lead to unintentio-
nal combustion. Please refer to the instructions for the
use of your stove. See Figure 1 – example of safety di-
stance to combustible walls for a Scan-Line 500 stove.
Combustible wall
Safety area
60°
60°
1230
Figure 1
Degree of rotation 180°
Pivot centre
The pivot centre of the stove is centred through the
rotation spigot directly into the centre of rotation of
en
Degree of rotation 120°
Combustible wall
Safety area
90°
90°
1230
the rotating base. The rotating base is factory set to
turn 180º, i.e. to turn 90º to each side.
Figure 2
Pivot centre
for stove and
chimney.
Centre
screw
Rotating
base
Changing the turning angle
If the stop screw is removed, the rotating base can turn
through 360º. See Fig. 2.
If you wish to reduce the angle of turn to 120º, remove
the stop screw and invert the rotating base. See Fig. 3.
Turn the base plate to 120º. The arrow points directly
at the hole for the stop screw. Turn the rotating base
once more, and fit the stop screw.
Figure 3
Fig. 3
End stop
120°
6
Rotation spigot
Stop screw
180°
Base plate

Publicité