Installer Settings: Tables To Be Filled In By Installer; Quick Wizard; Space Heating/Cooling Control; Domestic Hot Water Control [A.4] - Daikin Altherma EHBH04CA3V Manuel D'utilisation

Masquer les pouces Voir aussi pour Altherma EHBH04CA3V:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.7
Installer settings: Tables to be filled in by
installer

3.7.1 Quick wizard

Setting
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
BUH type
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
Space heating/cooling settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW operation
DHW tank heater
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Solar kit
Alarm output
Bottom plate heater
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter
External kWh meter
Capacities (energy metering) [A.2.3]
Booster heater
BUH: step 1
BUH: step 2
Bottom plate heater
EHBH/X04+08+16CA + EHVH/X04S18CA+EHVH/X08+16S18+26CA
Daikin Altherma - Low Temperature Split
4P313773-1 – 2012.05
Default
Fill in...
1 (1P,(1/2))
0 (LWT
control)
0 (In room)
1 (1 LWT
zone)
1 (1 LWT
zone)
1 (Sample)
Depends on
model
Depends on
model
0 (No)
2 (Thermo
ON/OFF)
2 (Thermo
ON/OFF)
0 (No)
0 (No)
0 (No)
0 (Normally
open)
0 (No)
0 (No)
0 (No)
0 (No)
0 kW
Depends on
model
Depends on
model
0 W

3.7.2 Space heating/cooling control

Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Set weather-dependent heating
Set weather-dependent cooling
Leaving water temperature: Delta T emitter [A.3.1.3]
Heating
Cooling
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type

3.7.3 Domestic hot water control [A.4]

Setting
Setpoint mode
Setpoint readout type
Maximum setpoint

3.7.4 Contact/helpdesk number [6.3.2]

Setting
Contact/helpdesk number
4

Energy saving tips

Tips about room temperature
Make sure the desired room temperature is never too high (in
heating mode) or too low (in cooling mode), but always
according to your actual needs. Each saved degree can save up
to 6% of heating/cooling costs.
Do NOT increase the desired room temperature to speed up
space heating. The space will NOT heat up faster.
When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperature and do NOT let the room temperature drop too low.
It will take more time and energy to heat up the room again.
Use a weekly schedule for your normal space heating or cooling
needs. If necessary, you can easily deviate from the schedule:
For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when
you are leaving for a couple of hours.
For longer periods: You can use the holiday mode.
Example: When you stay at home during your holiday, or
when you go away during your holiday.
4 Energy saving tips
Default
Fill in...
0 (Absolute)
25/40/15/–10
18/22/35/20
0 (Absolute)
25/40/15/–10
18/22/35/20
5°C
5°C
0 (No)
1 (Slow)
Default
Fill in...
0 (Reheat only)
0
(Temperature)
Depends on
model
Default
Fill in...
Operation manual
6

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières