Thermal dissipation and current drawn
NXAMP4x1mk2 with 2 Ohms load on each channel
Line Current (A)
120 V
230 V
Idle
1.5 A
1.0 A
1/8 Max
8.9 A
4.9 A
power
1/4 Max
16 A
8.5 A
power
NXAMP4x4mk2 with 2 Ohms load on each channel
Line Current (A)
120 V
230 V
Idle
2.7 A
1.9 A
1/8 Max
28.0 A
14.6 A
power
1/4 Max
53.9 A
26.5 A
power

Drawings and dimensions

NXAMP4x1mk2 and NXAMP4x2mk2
NXAMP4x4mk2
Thermal
Watts
Dissipation
Dissi-
pated
BTU/h
kcal/h
161 W
549
138
397 W
1355
341
592 W
2020
509
Thermal
Watts
Dissipation
Dissi-
pated
BTU/h
kcal/h
270 W
921
232
1037 W
3539
892
1771 W
6044
1523
480 mm
480 mm
NXAMP4x2mk2 with 2 Ohms load on each channel
Line Current (A)
120 V
230 V
Idle
1.8 A
1.1 A
1/8 Max
15.7 A
8.2 A
power
1/4 Max
29.1 A
14.5 A
power
Thermal
Watts
Dissipation
Dissi-
pated
BTU/h
kcal/h
190 W
648
163
607 W
2072
522
980 W
3344
843
88 mm
132 mm

Publicité