tbs electronics PSC1600-12-60 Mode D'emploi page 22

Masquer les pouces Voir aussi pour PSC1600-12-60:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Charge current is too low.
Mode indicator LEDs
'inverter on', 'charger on'
and 'AC in' are blinking red
once per second (battery
error).
Only mode indicator LED
'inverter on' blinks red once
per second.
Only mode indicator LED
'inverter on' blinks red twice
per second.
Additional battery loads are
consuming too much current
during charging.
High ambient temperature.
Charger is operating in the
absorption charging stage.
Battery voltage is too low (<
8V@12V or <16V@24V).
Battery voltage is too high
(>16.5V or >33V@24V).
Too high ripple voltage on DC
input. (manual restart
needed)
Battery voltage is too low
(<10V@12V or <20V@24V).
Inverter is overloaded.
Connected AC output load
causes a short circuit.
21
Turn-off or disconnect all
battery loads.
Try to lower the ambient
temperature around the
Powersine Combi.
Do nothing. The battery is
almost fully charged and
consumes less current by
itself.
Battery is damaged, replace
it. Or battery has been
discharged too extremely, let
it slowly recover to above
8.5V so that the transfer
switch and charger can
startup to recharge the
battery.
Check the DC system for an
external source that pushes
the battery voltage too high.
Check battery wire
connections. Decrease
battery cable length.
Increase battery and/or
cable size. Make sure that no
other equipment on the
same battery is generating a
high ripple voltage.
Apply mains voltage to the
AC input and start charging
the battery.
When another turn off
voltage is desired in 'Battery
protect On' mode, please use
Dashboard
Make sure that the total
power rating of the AC
output load is lower than the
nominal inverter power
rating.
Make sure that the AC
output load is not defective.
Check if the AC output wiring
and connections are not
creating a short circuit.

Publicité

Table des Matières
loading