The frontpanel can be divided into four sections :
1. Dual function level bar. Indicates the percentage of delivered output power in inverter
mode (turns red if more than nominal output power is being delivered to the load). In
charger mode, this level bar indicates the percentage of delivered charging current.
2. Mode indicators. Indicate the operating mode of the Powersine Combi, as well as the
status of each different mode (see explanation below) :
'charger on' LED
'inverter on' LED
'AC in' LED
Off
On (green)
On (blinking red)
On (red)
Off
On (green)
On (blinking red)
On (red)
Off
On (blinking green) : AC input present and within range, Powersine
On (green)
On (blinking red)
On (red)
: not charging
: charging
: error (see chapter 4.2.1)
: charger disabled
: not inverting
: inverting or power boosting
: error (see chapter 4.2.1)
: inverter disabled
: No AC input present, transfer switch open
Combi is synchronizing
: AC input approved, transfer switch closed
: AC input present but out of range
: AC transfer switch disabled