5.5 Calibrate sensor
You can calibrate the sensor in Celcia 20 by hanging an accu-
rate thermometer next to the controller. The menu contains
Sensor Adjust for that. For instance, if the controller is
indicating 0.2 °C too low, set the value at +0.2 °C.
1
Set the rotary knob on MENU.
MENU
2
Go to
S S E E T T T T I I N N G G S S
and press OK.
3
Go to
M M I I S S C C E E L L L L A A N N E E O O U U S S
and press OK.
4
Now select
W W A A L L L L C C O O M M P P
and set the appro-
priate correction value. Confirm with OK.
5
Return the rotary knob to the desired pro-
gramme and close the lid.
Fig. 13 Calibration
ENGLISH
5.6 Set control parameters
Because there are different types of heating systems, there are
also different control parameters. The following table shows
the optimal settings for 3 types of systems.
P-value
Floor heating
5
Radiators
15
S S E E T T T T I I N N G G S S
The influence of the set control parameters is as follows:
P-value: in the case of a greater value the Celcia 20 reacts
M M I I S S C C E E L L L L A A N N E E O O U U S S
fiercely to changes in the desired room temperature
I-value: in the case of a greater value the Celcia 20 adjusts
in the long term calmly to the set temperature.
W W A A L L L L C C O O M M P P
1
Set the rotary knob on MENU.
MENU
2
Go to
S S E E T T T T I I N N G G S S
and press OK.
3
Go to
C C O O N N T T R R O O L L L L E E R R
and press OK.
4
Go to
C C O O N N T T R R O O L L
and press OK.
5
Now select
P P _ _ V V A A L L U U E E
and select the value
you want. Confirm with OK.
38
I-value
95
85
S S E E T T T T I I N N G G S S
C C O O N N T T R R O O L L L L E E R R
P P _ _ V V A A L L U U E E