Access To The Configuration Menu - REMA DSD04 Série Mode D'emploi

Masquer les pouces Voir aussi pour DSD04 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. CONFIGURATION
To adapt the Dynamometer 04 to different use conditions, it's possible to configure the main parameters. It's possible to select:
UNIT OF MEASURE : Kilo [Kg], Ton ( t ), Short-ton [ton], Pounds [lbs], DecaNewton [daN], KiloNewton [kN].
POWER OFF : Enable ( after 20 minutes of inactivity), Disable.
Reading resolution: 1,2,5,10, 20,50 apart from the selected unit of measure (Default layout : 2 ).

3.1 ACCESS TO THE CONFIGURATION MENU

You can enter the configuration menu by pushing " TARE " and " PEAK " at the same time; with the buttons TARE
used individually you can select the heading to modify and by pushing " HOLD "
menu.
3.2 LAYOUT OF THE UNIT OF MEASURE.
Enter the configuration menu as described above; with the buttons or select the heading UNIT and push . The instrument will
display UNIT on the upper part of the display while on the lower the current unit of measure is visualized. Select the unit with the
buttons or  and confirm by pushing  : " OK " will be visualized for some seconds and then you can come back to the first
configuration menu: push the buttons  and  at the same time to come back to the normal running.
Conf
UNIT
ON
PEAK
TARE
OFF
3.3 RESOLUTION LAYOUT
Enter the configuration menu as described in 3.1; with the button or select the heading RESOL and push
 the instrument will display RESOL on the upper part of the display while on the lower the current layout is
visualized. Select the resolution with the buttons or and confirm by pushing : " OK " will be visualized
for some seconds and then you can come back to the first configuration menu; push the buttons andat
the same time to come back to the normal running.
Conf
RESOL
ON
PEAK
TARE
OFF
CAUTION!
By pushing " TARE ", " PEAK " and "HOLD" at the same time you enter the calibration menu. Only authorized
personnel can start this procedure; we tell you to quit the calibration menu immediately by turning off the
dynamometer with ON/OFF key.
0
kg
ON
TARE
PEAK
HOLD
OFF
Unit
LBS
ON
HOLD
TARE
PEAK
OFF
rESol
ON
TARE
PEAK
HOLD
OFF
Conf
UNIT
ON
TARE
PEAK
HOLD
OFF
Conf
UNIT
ON
HOLD
TARE
PEAK
OFF
Conf
RESOL
5
ON
HOLD
TARE
PEAK
OFF
34
Unit
kg
ON
OFF TARE
PEAK
HOLD
you can enter the modification
LBS
ON
HOLD
TARE
PEAK
OFF
LBS
ON
HOLD
TARE
PEAK
OFF
or PEAK
0
HOLD
0
HOLD

Publicité

Table des Matières
loading

Table des Matières