3.
ADVANCED CONFIGURATION (for technicians only)
The codes that are found in the unit are:
02000
Reception of the programme and the transmitter's version: switch on the transmitter
after switching on the instrument.
Continue with TARE.
Now, a value that corresponds to the intensity of the reception field will be
displayed.
Confirm with MODE.
00531
Serial configuration
Choose between enabling the serial output:(S SI) or inhibiting it (S no) with MODE.
Continue with TARE.
Select the transmission rate with MODE (1200, 2400, 4800, 9600, 19200, 38400).
Note: if used in receiving mode, the baudrate is 2400
Continue with TARE.
Choose the transmission type: continuous (Conti), with repeater (riPEt), with printer (StAMP) with
MODE.
Continue with TARE.
If you chose continuous transmission, you can enable the transmission of the measurement unit ( U
SI – U NO) by pressing MODE.
If you chose transmission with repeater, you can choose the number of digits to be transmitted (C 5
or C 6) by pressing MODE.
If you chose transmission with printer, you can choose the printer type: 80 columns (S 80c), 24
columns receipt (S 24c), 24 columns on one sole line (S 24L)
.
00400
Calibration code
Enter the code and press MODE for a long time to continue with the setting, Choose
the division value with MODE and TARE, confirm by pressing MODE for a long time.
Perform the zero setting by pressing MODE. Load a weight and press TARE, set the
loaded weight value and press MODE for a long time. If necessary, also calibrate the
following steps.
00022
Various configurations
Enter the code and press MODE to continue with the setting, the various parameters
are:
P Min (n) This parameter is the weight value within which the weighing is considered to be minimum.
The measurement unit is the same as that of the displayed weight.
T 0tr (t) This parameter defines a time range which, once over,
causes any zero variations to be compensated.
R 0tr
P MAS
T PS
R PS
(r)
This parameter defines a weight range within which all zero
variations need to be compensated.
(P)
(If envisaged), it defines a weight value which, once
exceeded, causes the display unit to lock out the reading of
weight and display
(S)
.This parameter defines a time range which, once elapsed,
causes a weight that is not moving to be considered as
stable.
(c)
This parameter defines a weight range within which a weight
is considered to be stable
14