Cable Connectors - LOTRONIC AFX LiGHT BLADE5-FX Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Features
7/24/30/36 DMX channels
5x 12W 4-en-1 CREE LED
Beam angle 8°
Infinite Pan & Tilt rotation at 360°
Dynamic built-in programs
Modes : DMX, sound activated, master-slave
Specifications
Power supply .......................................................................................... 90-240Vac 50/60Hz
Consumption .................................................................................................................. 90W
Pan & Tilt rotation .......................................................................................................... 360°
Dimensions .................................................................................................... 65 x 18 x 25cm
Weight ......................................................................................................................... 10,5kg
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure
and able to support a weight of 10 times of the unit's weight. Also always use a safety cable that can hold 12 times
the weight of the unit when installing the fixture.
The equipment must be fixed by professionals at a place where is out of the reach of people and where nobody can
pass by or under it.
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
Fuse Replacement
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
cables that can carry a high quality signal and are less prone to electromagnetic interference.

CABLE CONNECTORS

Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
©Copyright LOTRONIC 2017
COMMON
DMX +
INPUT
DMX-
BLADE5-FX
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.
Page 3

Publicité

Table des Matières
loading

Table des Matières