11. Troubleshooting guide

Faults
The equipment
- Power supply not connected
does not start
- Floating switch does trigger
The equipment
- Intake sieve clogged
does not pump
- Discharge hose kinked
The equipment
- Floating switch cannot sink
does not cut out
Insuffi cient pumping
- Intake sieve clogged
rate
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
The equipment swit-
- Motor circuit-breaker switches the
ches off after briefl y
equipment off due to excessive wa-
running
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment off
Anl_GH_DP_7835_SPK1.indb 20
Anl_GH_DP_7835_SPK1.indb 20
GB
Cause
- Check power supply
- Raise position of fl oating switch
- Clean intake sieve with water jet
- Unkink the hose
- Place equipment correctly on shaft
bottom
- Clean intake sieve
- Clean equipment and replace wear
parts
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
- 20 -