Introduction; Principle Of Operation; Preparations; Use - THERMOBILE BX 3 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
English
2

INTRODUCTION

2.1
Purpose
This portable heater works electrically and is
equipped with a fan. The heater has been
designed for horizontal indoor installation
(which can be permanent).
2.2

Principle of operation

Heating elements have been installed in the
heater.
The fan blows air over the heating elements.
The fan can be controlled continuously and
thermostatically.
The maximum thermostat switches off the
heater when overheated. Overheating occurs
when the air flow is too low or when the shaft
is dirty on the inside. Once it has cooled
down, the heater will switch on automatically
(automatic reset).
Make sure thereafter that there is better air
flow.
2.3
Main components (Fig. 4)
A
Operating panel
B
Fan
C
Supporting bracket
D
Mains plug
E
Suspension eyes
F
Air-inlet grid
G Heating elements
H
Air-outlet grid
2.4
Control thermostat
The heater has a control thermostat that
switches off the heater when the ambient
temperature set in advance has been
reached.
The BX9 and BX15 heaters have a
thermostat with double switching capacity.
2.5
Operating panel (fig. 3)
The heater has a 7-position selector switch
(A) and a control thermostat (B).
A
Selector switch
*
0 = Off
1 = Ventilate (BX 9 limited capacity).
14
B
Control thermostat, infinitely variable
from 0 - 35 °C
3
3.1
1. Remove packaging from the heater.
2. Check the contents for any damage.
3. Read the instructions for use.
3.2
1. Check whether the heater is connected
to the correct voltage/frequency.
2. Make sure that the heater has a stable
set-up.
3. Use the suspension eyes if the heater is
being suspended. Respect in this case
the sizes listed on the label (B), figs. 2 &
5.
4
4.1
Heat:
40.020.959 - rev. 01 - 2007
2 = Heat, half or 2/3 capacity. (The
fan is thermostatically controlled.)
3 = Heat, maximum capacity. (The
fan is thermostatically controlled.)
4 = Ventilate, do not heat
(BX9 ventilates to full capacity)
5 = Heat, half or 2/3 capacity. (The
fan is continuously controlled.)
6 = Heat, maximum capacity. (The
fan is continuously controlled.)

PREPARATIONS

Remove packaging
Installation
Warning
Do not connect the heater if the
voltage/frequency deviates from the
values as listed on the nameplate.
Always set the heater horizontally
with the foot caps at the bottom.

USE

Switching on (fig. 3)
BX3 / BX9 / BX15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bx 9Bx 15

Table des Matières