STANDARD OPERATION OPTIONS
BISTABLE OUTPUT
If the output is set as bistable, on each radio control command the output changes status. The
output has no magnetic retainer and therefore is deactivated in the event of a power failure and the
relay is activated.
TIMED OUTPUT
The timer interval is fixed at 20 seconds; this interval may be extended to 40 seconds (by soldering
bump contact A).
ON-OFF OUTPUT
If the output is set as ON-OFF channels 1° and 2°, 3° and 4° of the transmitter must be memorised
simultaneously on the required output.
In this way channel 1° or 3° of the radio control will always activate ON, while radio control channel
2° or 4° will always activate OFF.
SELECTION JUMPER
Selection of voltage at 12Vdc/Vac.
AERIAL
To improve radio control reception and capacity a suitable aerial should be installed.
To exploit performance to the full, the aerial should be secured to the highest possible point on a
suitably sized metal support. A cable with impedance of 50 ohm (e.g.RG58) should be used to con-
nect the aerial and receiver. This cable should not exceed 10 metres in length.
DISPOSAL
This product is composed of various components which may in turn contain pollutants.
Do not dispose of it in the environment! Find out about the method for recycling or dis-
posing of the product in compliance with current local laws