Key Automation 900RXI-41 Manuel D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
900RXI/M-41 900RXI/M-41R 900RXI/M-42 900RXI/M-42R
LR1 LR2
S
P
+
-
gnd sign
12/24 VAC/VDC
Power supply
OUT 1
Relay 1 output
OUT 2
Relay 2 output (only on RXM-42/42R or RXI-42/42R)
AERIAL
Aerial input
STANDARD OPERATION
When powered up, the receiver performs aninternal test and leds LR1-LR2 emit two slow and two fast
flashes to indicate that it is ready for the next phases.
STANDARD CODE SELF-LEARNING
The output to be programmed is selected by means of pushbutton P, or Out1 is entered automatically. At this
point led LR (selected) emits a series of slow flashes for 10 sec. To indicate entry in the self-learning phase.
In this interval, if the radio control is pressed self-learning of thecode is activated with the channel on which
it is transmitted. If the code is memorised correctly, leds LR1, LR2 remain lit for 2 sec. After the first memo-
risation command, the leds flashfor a further 6 sec. On standby for a new memorisation command;if this is
performed, they continue to flash for 6 sec. Otherwiseit exits the programming phase. If a previously memo-
rised codeis entered during this phase, leds LR1 and LR2 flash quickly to indicate that the code has already
been memorised.During the self-learning phase, each output canmemorise up to approx. 400 codes.E.g. an
initial user can memorise channel 1° of the radio controlin output Out1 of the receiver, and a second user
can memorise channel 2°, 3° or 4° on the radio control in the same output (Out1) of the same receiver.
OUTPUT PROGRAMMING
The selection push button S enables the user to select the output to be programmed (Out1,Out2), and dis-
plays the latter by means of the indicator leds LR1 and LR2. Each time pushbutton S is pressed, a different
output is selected, changing from LR1 to LR2, in the sequence LR1-LR2-null-LR1-..... After selecting the
output to be programmed, programming pushbutton P enables entry of the output as monostable (1 flash
of led LR), bistable (2 flashes of led LR), timed (3 flashes of led LR) and ON-OFF (4 flashes of led LR).
Pushbutton P varies the number of flashes of an output and thus its programming. Therefore outputs can be
programmed differently from one another. E.g. Out1 set as impulse type, Out2 set as step.
N.B. If no output is selected by means of pushbutton S, pushbutton P automatically programs the first output
when pressed.
A
NA NA
Prolung. Timer
NC NC
7
900RXM230-42
Prolung. Timer
S
P
230Vac
OUT1
OUT2
LR1 LR2
ANT

Publicité

Table des Matières
loading

Table des Matières