To improve Cooling/Heating effect
When only poor cooling/heating effect is obtained due to installation place of the indoor unit or construction of the room, the detection
temperature of cooling/heating can be changed.
• Remove the cover of the electric parts box by taking off the mounting screws (3 positions) and pushing the hooking section. (The
cover of the electric parts box remains hanged to the hinge.)
• There are the selector switches (SW01) on the P.C. board of the electric parts box.
The setting of the detection temperature can be changed by combining No.1 to No.4 switches of the selector switches (SW01).
Adjust the setting of the detection temperature according to the table below.
Setting at shipment
EN
No.1
No.2
No.3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
COOL/DRY
No.4
(°C)
OFF
–2
OFF
–2
OFF
–2
OFF
–2
OFF
+4
OFF
+4
OFF
+4
OFF
+4
ON
+2
ON
+2
ON
+2
ON
+2
ON
0
ON
0
ON
0
ON
0
22
HEAT
(°C)
–2
+4
+2
0
–2
+4
+2
0
–2
+4
+2
0
–2
+4
+2
← Factory setting
0