The scan priority order is :
1.Wired 3D signal
2.DLP-link 3D signal
3.IR 3D signal

3.3 Selecting the emission channel

This option is only available with EDGE
VR and
TM
ActivEyes
Pro
TM
The emission mode is selected by the function selector:
0 : Autotest mode
3 to E: RF channels
8 : Default RF channel
F: VESA channel
Please note that the position 1 and 2 are not to be used
in the ActivHub
RF50.
TM

3.4 Examples of setups

1.VESA-DIN3 > RF mode
1. Set the function selector to position 8.
2. Plug the Vesa or BNC connector to your 3D source
3. If using the BNC cable, plug its USB connector to a
power source.
4. Plug the Jack 3.5 connector to the ActivHub
RF50.
TM
5. Check the blue LEDs light up to signal power on.
6. Check the blue LEDs starts blinking twice every 3 sec.
Notes:
• The ActivHub
RF50 blinking twice means a functional
TM
signals 3D sync input and its RF transmission.
• If you experience interferences, or if you are using
many ActivHub
RF50 in a single room or building, you
TM
may choose another channel between 3 and E.