5.

Application

1370 00 24-R, 1370 00 24-R01:
Basic installation kit for hydraulic AQUALINE-Therm self-closing thermostatic mixer
DN 15, for in-wall installation for shower facilities. For connection to the hot and cold
water supply.
1370 00 24-R02, 1370 00 24-R03:
Basic installation kit for electronic, time-controlled AQUATIMER thermostatic mixer
DN 15, for in-wall installation for shower facilities. For connection to the hot and cold
water supply.
6.

Scope of Delivery

1370 00 24-
R
R01 R02 R03
1
1
1
1
2
2
1
1
1
1
1
1
7.

Dimensions

8.

Installation Example

9.

Assembly Instructions

9.1
Mount the in-wall installation box horizontally into the recess provided for this
purpose and fasten.
Important!
While turning the union nut (a), use an open-end spanner to hold the water volume
regulator (b) in place.
9.2