Télécharger Imprimer la page

Daspi PIXEL Manuel D'utilisation Et D'installation page 3

Centrale de commandes pour portails coulissants 24 vcc

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 5
1 • GENERAL SAFETY INFORMATION ATTENTION: It is prohibited to carry out any kind of assembly, repair or adjustment to the apparatus by
EN
unqualified staff, and if the necessary precautions haven't been taken and electricity supply disconnected (including any back-up batteries), in order
to avoid any possible accident or injury, DASPI will not be responsible for any damage or injury to people, animals or objects resulting from improper
use of the apparatus or for use other than what is specified in this instruction booklet, and/or resulting from any modification carried out on this product
and its components. This control panel is not suitable for installation in an explosive atmosphere. Keep this manual with care, enclose it to the technical
installation file and keep them in a suitable an convenient place known by whoever is concerned, for future reference.
2 • PRODUCT TYPE The PIXEL control panel has been designed to operate a motor 24 Vdc for sliding gates. It is supplied with an electronic clutch and has a radio
receiver incorporated.
3 • TRIMMERS
Pause time from 1 to 120 seconds with trimmer set on the maximum TCA unable
TCA
OP PWR
Opening torque
CL PWR
Closing torque
4 • PROGRAMMING AND SETTING THE CONTROL PANEL
Switching DIP-SWITCHES must always be carried out with control panel disconnected from the electricity mains
SW1
ON
1
To enable 3 seconds pre-opening flashing light
2
To disable START command while gate is opening (residential mode)
3
To activate additional feature "Close after passing through photocells".
Attention! This feature can be activated only with photocells connected to
output 13-14
4
High sensitivity during slowing down
5
To make terminal 17 to work as courtesy light output
6
To activate PHOTOTEST feature. Attention! This feature can be activated only
with photocells connected to output 12-13. Before each operation the control
panel checks if contact of photocells is open. If not open flasher remains
steadily on and the gate does not work.
LED TABLE
DL1
Red LED to indicate use of START button command on control panel
DL2
Red LED indicates the programming input mode and the various phases
that can be activated using the PRGM button on the control board
Green LED lights up when the PED contact closes.
DL3
DL4
Green LED lights up when the START contact closes
DL6
Red LED lights up when the STOP contact opens
DL7
Red LED lights up when PHOTO contact opens. With photocells
connected to output 12-13 and gate still it remains lit up; it switches off
when gate starts and it lights up again at the opening of the photocell
contact.
In case LED indications do not match the table above, check connections and proper order of connected devices.
5 • RECEIVER
433.92 MHz radio receiver Storing capacity up to 256 remote controls (Tx) with different codes.
STORING REMOTE CONTROLS.
After connecting to the electricity mains the control panel, LED2 should lights up for 1 second.
If this does not light up, or if both LED1 and LED2 simultaneously light up, contact Customer Services.
1 - Press INS button on the panel for storing a START command, or press DEL/PED on the panel for storing a pedestrian command. LED2 lights up.
2 - Push the desired remote control button twice to store the radio code. The first push will make LED2 turns off and then on, while the second push will make LED2
flash 3 times to indicate that radio code has been stored. If something goes wrong, the procedure terminates without the 3 flashes of LED2.
Once INS or PED/DEL button on the receiver has been pressed and after the first push on remote control storing procedure must be complete in 10 seconds. In
case the same remote control button is mistakenly stored for both START and PED pedestrian command , the gate won't work and LED1 will flash. If this occurs, t
code must be deleted (as described below) and stored again in the correct command.
DELETING RADIO CODES
Keep DEL/PED button pressed for 5 seconds: LED1 and LED2 will light up. From now on deleting procedure is the same as storing procedure:
Push the remote control button twice to delete radio code. The first push will make LED2 turns off and then on, while the second push will make LED2 flash 3 times
to indicate that radio code has been deleted. If something goes wrong, the procedure terminates without the 3 flashes of LED2.
Once INS or PED/DEL button on the receiver has been pressed and after the first push on remote controlstoring procedure must be complete in 10 seconds.
DELETING ALL RADIO CODES
Keep DEL/PED button pressed for 10 seconds: LED1 and LED2 will flash 3 times to indicate that all radio codes have been deleted.
N.B. If inputs which are normally closed (N.C.) are not being used, they must be bridged. If more than one N.C. contacts are used on the same terminal inputs,
they must be connected in series. If more than one N.O. (normally open) contacts are used on the same input they must be connected in parallel.
OFF
No pre-opening flashing light
START command active also while gate is opening , the gate stops
Function not activated
Low sensitivity during slowing down
To make terminal 17 to work as gate open warning light output
Function not activated
DL8
Red LED lights up when the SAFETY EDGE contact opens
DL10
Red LED lights up when the FCC contact opens
Red LED lights up when the FCA contact opens
DL11
LED1
Red LED indicates of radio codes
LED2
Red LED indicates of radio codes on PED button or the cancellation of
existing ones
1
Antenna input to connect the 'hot' pole of the antenna to terminal 1
2
and the braid to terminal 2
3
PED Input activates pedestrian opening when the gate is closed and
5
it closes the gate when it is open.
START input open the gate when it is closed, it stops the gate while
4
opening (if DIP2 = OFF), it closes the gate when the gate is opening,
5
and open during closing
5
STOP Input. If activated it stops every movement.
6
PHOTO input with DIP3 = OFF gate reverses movement during closing
7
and during opening it is ignored. With DIP3 = ON during closing it
9
stops the gate and after clearing photocells it closes again. During
opening it stops the gate and after clearing the photocells, it closes.
8
SAFETY EDGE Input (COSTA).
9
9
Input for closing limit switch
10
N.C. contact
9
Input for opening limit switch
11
N.C. contact
Output power only during movement of the gate for photocells. Useful
12
for energy saving while gate is still and mandatory in order to use
13
feature PHOTOTEST DIP6=ON. It is possible to wire only 2 pairs of
photocells (max 150mA)
GREEN = 0V
1 2 3 4 5 6
CL
OP
TCA
BROWN = +5V
PWR
PWR
ENCODER
DL1
J1
SW1
WHITE = SIGNAL
- +
- +
- +
START PRGM
LED1
INS
LED2
DEL/PED
T1
J2
F1
24 Vac
6 • PROGRAMMING
It must be carried out after installing all safety devices, in order to reduce risk of injury.
Preliminary checks:
• Connect control panel to the electricity mains.
• Check that all LEDs are switched off. If photocells are powered through output 12-13 LED DL7, must be switched on.
Programming:
1. N.B. The gate must be closed and the closing limit switch engaged LED DL10 = ON.
2. Hold button PRGM down until led DL2 begins flashing and then remains steady.
3. Give a 1
st
START command (or remote control command previously stored as in the instructions), the gate opens.
4. While opening is almost completed, give a 2
nd
START command, to fix opening slowing down. The gate will continue the travel until the opening limit switch is
engaged and the led DL2 turns off. After 3 seconds the gate closes automatically.
5. While closing is almost completed, give a 3
rd
START command to fix slowing down in closing. The gate will continue the travel until the closing limit switch is
engaged. After 3 seconds the gate opens automatically.
th
6. Once reached the desired pedestrian opening, give a 4
START command, the gate is stopped and this fix the partial pedestrian opening. After 3 seconds the
gate closes automatically and the programming is now completed.
If within 10 seconds from point 2 the sequence of programming is not started, led DL2 turns off and the procedure is terminated automatically.
During programming procedure any STOP command or photocell intervention will cause the termination of programming procedure (The gate stops, the led DL2
turns off and program is cancelled). It is mandatory to follow strictly the sequence described above.
Adjustment:
• Operating trimmers CL PWR - OP PWR are for adjusting the torque, in order to make the gate stop as required by regulations and carry out the necessary
measurements.
• Exceeding the set torque level will make the anti- crushing feature intervene: while closing the gate reverses the movement until complete opening, during
opening it reverses the movement for about 10 cm and it stops. Attention! In case of intervention for 3 consecutive times of anti-crushing feature during closing,
the gate will remain open and the automatic closing (if activated) will be disabled. It is now required a start command closing of the gate.
• Set the length of the pause time using trimmer TCA (from 1 to 120 seconds with trimmer set on the maximum TCA unable)
Give information to people involved in the use of the gate about operations and commands, safety devices and any danger arising from the use of the automation.
Fill in the technical installation file and comply with current regulations.
Permanent output power to photocells. Attention! Use only with
13
feature PHOTOTEST disabled DIP6 = OFF otherwise the gate won't
14
work and the blinker lights up steadily. 14+/13- (max 150mA)
15
Output for additional accessories 24Vdc 13-/15+ (max. 500mA)
13
15
Flashing light output: intermittent output 24Vd DC max 10W
16
SPIA Output DIP5 = OFF, fast flashing light during closing, slow flashing
15
during opening, continuous light when gate is open, flasher switched
17
off when gate is closed
15
Courtesy light output DIP5 = ONlight on for 120 seconds
17
(24 Vac Max 10W)
18
Backup battery input
19
T1
Motor output 24 Vdc.
T2
J1
ENCODER connector
J2
Connector for secondary input of the transformer 24 Vac
1
ANT
RX433
2
DL2
DL3
3
PED
DL4
4
START
5
COM
1 2 3 4 5 6
DL6
6
STOP
DL7
7
FOTO
DL8
8
COSTA
9
COM
DL10
10
FCC
DL11
11
FCA
+ 24 Vdc FOTOTEST
12
13
- 24 Vdc
14
+ 24 Vdc
15
16
LAMP
T2
17
SPIA
18
- BATT
19
+ BATT
M
1 2 3

Publicité

loading

Produits Connexes pour Daspi PIXEL