Operating Instructions
Transducer for active power DW5-xxxx
Safety precautions to be strictly observed are marked
with following symbols in the Operating Instructions:
The instruments must only be disposed
of in the correct way!
Contents
1. Read fi rst and then ................................................... 11
2. Brief description ........................................................ 11
3. Technical data ........................................................... 11
4. Mounting ................................................................... 12
5. Electrical connections ............................................... 12
6. Commissioning and maintenance ............................. 14
7. Releasing the transducer .......................................... 14
8. Dimensional drawing ................................................. 14
9. Instruments admissions ............................................ 14
10. Declarations of conformity ........................................ 15

1. Read fi rst and then ...

The proper and safe operation of the device
assumes that the Operating Instructions is
read carefully and the safety warnings given
in the various Sections
4. Mounting
5. Electrical connections
are observed.
The device should only be handled by appropriately
trained personnel who are familiar with it and authorised
to work in electrical installations.
Unauthorized repair or alteration of the unit invalidates
the warranty!

2. Brief description

The transducer DW5-xxxx converts to active power of a
three-phase system with balanced or unbalanced loads.
The output signal is proportional to the measured value of the
active power and is either a load independent DC current
or a load independent DC voltage.
7004-00058-A Rev A.indd

3. Technical data

Measuring input
Measured quantity:
Nominal frequency:
Nominal input voltage: ≥ 100 to 690 V
Nominal input current: ≥ 1 to ≤ 6 A
Measuring output
DC current:
Burden voltage:
External resistance:
DC voltage:
External resistance:
Time response:
Power supply
AC/DC power pack (DC or 40 - 400 Hz)
Rated voltage
85 - 230 V* DC, AC
24 - 60 V DC, AC
Power consumption:
Options
Connected to the low
tension terminal side:
Power supply from
measuring input
(self powered):
Please note the max. and min. measuring input
voltage!
Type label
inscription
Self powered
by 2/5
(int. 85-230 V)
Accuracy (acc. to IEC 688)
Reference value:
Basic accuracy:
Safety
Pollution degree:
Installation category:
* An external supply fuse must be provided for DC supply
voltages > 125 V.
Page 3 of 16
Active power,
unipolar or bipolar (in 4 quadrants)
50 or 60 Hz, sine
(85 - 230 V with power supply from
measuring input)
0 - 1 to 0 - 20 mA
0.2 - 1 to 4 - 20 mA
± 1 to ± 20 mA
± 15 V
See "5. Electrical connections"
0 - 1 to 0 - 10 V
0.2 - 1 to 2 - 10 V
± 1 to ± 10 V
See "5. Electrical connections"
< 300 ms
Tolerance
DC - 15 to + 33%
AC ± 15%
≤ 2.5 W resp. ≤ 4.5 VA
24 V AC or 24 - 60 V DC,
see Fig. 4
85 - 230 V AC, see Fig. 3
Input voltage
Tole-
range = internal
rance
power supply range
85 - 230 V AC
± 15%
Output end value
Class 0.5
2
III
Power
supply
connection
Internal
measuring
input
12/29/14