Technical Specifications - Extel SUNLIGHT 10 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
SAFETY INSTrUCTIONS
1
Important!
Please read the user manual thoroughly before installing or using this product.
If you install this product for other people, please give the manual or a copy to the end user
Warning:
The different elements can only be dismantled by an authorised technician. .
Safety instructions:
To safely use this system, it is essential the fitters, users and technicians follow the safety procedures described
in this manual.
Specific warnings and caution symbols are indicated on the elements if necessary
Warning:
Follow these instructions:
The only connections made should be those provided in this manual: making any incorrect connections could be
dangerous and could seriously damage the system.
In view of the risks that may arise during the installation and usage phases of the product components should be
installed in accordance with the following recommendations: Do not make any modifications of any kind to any
parts of the device unless those modifications are described in this guide. Unauthorised operation will only lead
to operating problems. The manufacturer accepts no liability for damage resulting from products that have been
modified arbitrarily.
dESCrIPTION
2
1 •
10W polycrystalline pre-wired (3m) solar panel, 12V
3 •
On/Off switch
5 •
3m cable (3 wire)
3
USAGE
a. Wiring:
Note: the panel and sockets are pre-wired.
- Cut the cable according to your installation (fig. 1)
1: panel connection to the control box
2: switch connection to the control box. The bridge is essential and must not be forgotten.
3: sockets connection to the control box
- Strip the cables in order for the connections to be made properly to the control box (fig.2)
- Follow the diagram carefully for correct system operation (fig.3)
Ensure that the connection polarities are respected.
b. Fastening the photovoltaic panel:
- To ensure optimum performance the photovoltaic panel must be positioned in such a way that it is able to capture
the maximum amount of solar power during the day. This means that the direction and angle of the panel must be
calculated according to its installation location.
recommendation: installing the photovoltaic panel at a 45° angle facing towards the South provides the opti-
mum conditions for capturing the maximum amount of solar power.
Use of a mounting bracket for fastening the selected panel angle to suit your needs is recommended (bracket not
supplied).
GB
CFI EXTEL SUNLIGHT 10 - 11/2010 - V1
2 •
Control box (with battery) 12V/7Ah
4 •
12V/5 W pre-wired (3m) LED light x2
- Select the appropriate location for installing the photovoltaic panel. The panel must receive the maximum amount
of sunlight during the day and during different periods of the year in order to operate correctly.
As a result the following checks must be made in order to verify whether the position selected is correct:
- Check that there is sunlight present for most of the daytime at the selected installation location.
- Check that the installation location is not surrounded by thick vegetation or anything capable of creating shade.
- Check that the direction and angle of the solar panel are correct.
Warning: initially the battery charge will not be at the optimum level. It takes several days of char-
ging for your system to reach optimum capacity.
This system will allow you to have lighting for around 5 hours per day (subject to optimum installa-
tion conditions and length of sunshine period).
4

TECHNICAL SPECIFICATIONS

a. Control box:
b. Photovoltaic solar panel
- Rated voltage: 12V
Rated voltage: 17.5V
- Rated battery capacity: 7 Ah
- Maximum power: 10W
- Operating temperature: -20°, +55°C
- Operating temperature: -40°, +85°C
- Dimensions: 280 x 210 x 110 mm
- Dimensions: 350 x 285 x 25 mm
- Weight: 1,385 kg
MAINTENANCE
5
It is advisable to clean the panel regularly for optimum recharge capacity. The guarantee is void if parts have been
dismantled. Clean the outside with a soft dry cloth only.
Warning: Do not use any carboxylic acid or alcohol-based or other similar product or solvent. In addition to the
risk of damage to your device, fumes are also dangerous to health and are explosive.
For cleaning purposes do not use any tool that may act as a voltage conductor (e.g. metal brush or sharp tool) or
that could potentially scratch the glass.
TECHNICAL ASSISTANCE - GArANTEE
6
Test :
A test button is available for checking that the system is operating correctly (a) (fig.3).
1. Set the switch to OFF (b).
2. Press the test button (a).
The green lights (c) («battery» and «solar») come on. The system is working properly. If this is not the case then
please see the instructions below.
CFI EXTEL SUNLIGHT 10 - 11/2010 - V1
c. LED light
- Rated voltage: 12V
- Maximum power: 5W
- Operating temperature: -20°, +50°C
- Luminous flux: 280 to 330 lm
- Base: E27