Safety Instructions; Assembly; Operation - Gardena 5500/5 Mode D'emploi

Pompe de forage
Table des Matières

Publicité

2. Safety instructions

Electrical Safety:
DANGER! Electric shock!
With a cut off mains plug, moisture can get
into electrical parts via the mains cable and
cause a short circuit.
v Never cut the mains plug off (e. g. to feed
through wall).
vDon't use the power cable for plugging off.
DANGER! Electric shock!
A damaged pump must not be used.
v In case of damage, please have the pump
checked by our GARDENA Service Centre.
v Before operating the pump, first make
a visual check, if there is any damage of
the pump (esp. regarding power cable and
plug).
In accordance with DIN VDE 0100, Deep Well
Pumps may only be operated in swimming
pools, garden ponds and fountains via
a residual current-operated-circuit-breaker
(RCD) with a nominal residual current
≤ 30 mA. The pump must not be operated
when there are persons in the swimming pool
or garden pond.
For safety reasons, we recommend operating
the Deep Well Pump with a residual current-
operated-circuit-breaker (DIN VDE 0100-702
and 0100-738).
v Please contact your electrician.
The power cable of the pump must be
connected to a socket which is positioned
at a height of max. 1.10m (measured from
ground). Take care that the power cable leads
downwards.
Data indicated on the type plate must match
technical data of the mains supply.
Only use extension cables authorised in
accordance with HD 516.
v Consult your qualified electrician.
v Take care that the electrical connections
are made within dry area, protected from
flooding.
v Keep mains plug dry.
10
Protect plug and power cable from heat, oil and
sharp edges.
The power cable must not be used for mount-
ing or relocating the pump. For submerging
or lifting / securing the pump, please use the
fastening rope.
In Austria:
In Austria, according to ÖVE B/ EN 60 555
part 1 to 3, pumps which are used in swimming
pools and garden ponds, and equipped with
firm power cable should be fed via an ÖVE
approved isolating transformer – rated voltage
must not exceed 230 V.
In Switzerland:
In Switzerland mobile appliances which
are used outdoors, must be connected via
a residual-current device.
Notes on use:
v Before operation, clear the pressure line
(e. g. open closed valve, closed outlet
connector etc.).
Running dry leads to increased wear or damage
and is to be avoided.
v The pump must be immediately switched off
when water fails to flow.
v Observe max. delivery height.
When connecting the pump to the water
supply system, the country-specific sanitary
regulations must be observed to prevent
water not of drinking water quality being drawn
back in.
v If necessary, contact your sanitary expert.
Sand and other abrasive substances
cause increased wear and reduce the pump's
output. Fibres in the water can block the
turbine.
During operation, the pump must always be
submersed in the water up to the minimum
submersion depth (see 9. Technical Data).
Do not allow the pump to run for more
than 10 minutes against the closed
pressure side (e. g. closed valve, closed
dispenser etc.).
The pump is automatically switched off
on overheating by the built-in thermal motor
protector. After having cooled down,
the motor automatically switches on again
(see 7. Trouble-Shooting).

3. Assembly

Install foot:
The foot enables the pump to stand steadily on the ground.
2
1
1. Push the foot
2. Screw the foot
When the pump is placed on the ground, the foot must be fitted
so that the pump does not draw in any sand or dirt particles.
2
Connecting the hose:
The 40mm (1 1/4") internal thread on the outlet of the Deep
Well Pump can be converted if necessary with the pump fitting
5
provided
then be connected to the GARDENA Hose Connection System
and the GARDENA Fitting Art. 1723 / 1724.
1. Screw the pump fitting
tighten it manually until the washer
6
3
2. Connect pressure hose
3. Tie the fastening rope
fastening rope.
4
For the best pumping results, connect 25mm (1") hoses with the
GARDENA Suction Hose Fitting Art. 1724 and one hose clamp.
If you need to disconnect the hose frequently from the pump,
we recommend using the GARDENA Pump Connection Set
Art. 1752 in connection with a 19mm (¾") hose.
The built-in non-return valve prevents the water flowing back
through the pump.
7

4. Operation

Pump water:
For the pump to work, it must be submerged in the water up to
the minimum water level on start-up
a) Without the foot, the pump must be fixed at least 20cm above
the ground.
b) If the foot has been fitted, the pump may be placed on the
ground.
9
1. Immerse pump on the fastening rope
6
8
The mains power cable must not be subjected to tension.
2. Secure the fastening rope
3. When using the pump in deep wells or shafts (from approx. 5m
a)
b)
deep) guide the connecting cable
6
using clips
4. Plug the power cable
h
Attention! The pump starts immediately.
>20 cm
1
onto the pump from below.
1
2
to the pump
with the two screws.
3
to a 33mm (1") external thread. The pump can
3
onto the outlet of the pump and
4
fits closely.
5
to the relevant adapter.
6
to one of the two eyes
7
ß
(see 9. Technical Data).
h
6
into a well or shaft.
6
.
8
along the fastening rope
9
.
8
into a mains socket.
for the
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

6000/514891492

Table des Matières