Fire Safety - WANDERS Solea Madera Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Height of chimney on the roof at a horizontal distance A measured from the ridge
Roof with
slope X
On the
ridge
o
25
0.5
o
30
0.5
o
35
0.5
o
40
0.5
o
45
0.5
• Any bends in the flue tube must not exceed 45
degrees.
• Ensure that the chimney tube can discharge the flue
gases adequately, properly and safely.
• The values for calculating the chimney tube is given
in the section on Technical Information, see above.
Fire Safety
For reasons of fire safety is it important to observe the
instructions below before installing the stove.
.
The free distance from the fire-proof rear wall is at
least 0 cm in each rotated position.
.
Keep at least a distance of 80 cm between the stove
and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects.
Keep the same distance from the flue tube.
.
Wooden construction parts within the radiation
range of the stove (80 cm from the exterior of the
stove) must be covered with fireproof material.
4.
If the flue tube goes through a ceiling and/or roof
that consist of flammable materials, the ceiling and
the roof must be covered with fireproof materials all
around (about 80 cm). Pay also attention to joisted
floor layers and any electric wiring.
5.
Keep a distance of at least 50 cm (in all directions)
between the stove and supporting steel construc-
tion parts.
6.
Shield off all combustible materials within a radius
of 80 cm from the stove openings with non-com-
bustible materials.
7.
The wall behind the stove must consist of, or be
insulated with, fire-proof materials. The insulation
material must resist a temperature of 700 °C and
have a density of 80 kg/m. Please see for insulation
materials table on page 4).
8.
Avoid heat transmission when placing the stove.
Heat transmission of a burning stove can penetrate
the wall and even cause fire damage on the other
side of the wall. Prevention is better than cure.
Horizontal distance A from the ridge, in metres
0.5 m
0.75 m 1 m
1.25 m 1.5 m
0.75
0.85
1.0
1.1
0.85
1.2
1.6
2.0
1.0
1.8
2.4
3.0
1.2
2.4
3.2
4.0
1.5
3.0
4.0
5.0
Installation
The Solea is tested in accordance with the international
EN 40 standardization, and has an extra additional
standardization for optimally environment-friendly
heating devices related to flue gases (Section 5a B-
Vg. Des BmfWA). The stove can be connected to a flue
tube to which several stoves are connected. The Solea
should never been integrated into the construction of the
room.
The heating device must be placed and connected by an
acknowledged installer and according to the installation
instructions given below. The national and local rules
and regulations for placing and using wood-burning
stoves are equally applicable. WANDERS does not give
any guarantee if the Solea is connected or installed
incompletely or incorrectly.
Supply of combustion air
The stove must have a sufficient fresh supply of
combustion air. To avoid draft, make if necessary an
extra air supply opening as close to the stove as possible.
An extra air supply opening is definitely required if:
The air supply opening must be sealable if it goes through
a fire-resistant wall. If there are several heating devices
in the same room there must be enough air openings to
guarantee proper combustion.
Connecting the fireplace
Be sure that the floor is strong enough to hold the weight
of the hearth without problem.
Before mounting the hearth, follow the instructions
given in the previous chapter. Protect the floor when you
mount the stove, and mind your back.
.
.
.
4.
2 m
3 m
1.2
1.6
2.5
2.4
3.2
4.9
3.6
4.8
7.3
4.8
6.4
10
6.0
8.0
12
the room has a heat recovery system.
the room has a central exhaust system.
the same space has a cooker hood.
To be rotatable, the Solea must be placed in line
with the inlet and outlet channels.
Connect the Solea Madera to an existing chimney.
The under-pressure in the flue tube must be 0 to 
Pa (0. to 0. millibars).
If external air supply is advisable, drill the desired
opening straight under the outlet channel, with a
diameter of at least 0 mm. Ensure that the stove is
4 m
3.3
6.5
10
13
16


Publicité

Chapitres

Table des Matières
loading

Table des Matières