Do not install, connect or remove your system during a lightning storm. If the storm is close enough for you to hear thunder, it is close enough to create
hazardous surges.
To avoid electric shock, use the transmitter indoors in a dry location only.
To prevent fires and electrical hazards, install the fence transmitter in buildings that are in accordance with state and local electrical codes.
If possible, DO NOT use an AC circuit protected with a Ground Fault Circuit Interrupter (GFCI). The fence system will function. However, in rare cases,
nearby lightning may cause the GFCI to trip. Without power to the system, your pet may escape. You will have to reset the GFCI to restore power to the
system.
To protect the transmitter, disconnect the boundary wire and unplug the power adaptor from the outlet when the system will not be used for long periods
of time or prior to thunderstorms. This will prevent power surges from damaging the transmitter.
Design Your Boundary Zone
Basic Planning Tips
Position your boundary wire and test the system before burying it. This will save you
time if you encounter a problem with the installation.
Running the boundary wire parallel to and within 3 m of electrical wires, neighbouring
containment systems, telephone wires, television or antenna cables, or satellite dishes
may cause an inconsistent signal. If you must cross any of these, do so at 90° angles
(perpendicularly) (4A).
Always use gradual turns at the corners to produce a more consistent boundary (4B).
Do not use sharp turns; this will cause gaps in your boundary.
Create off-limits areas inside the boundary using sections of twisted wire to run from
the boundary to the off-limits area (4C).
To properly contain your pet, we recommend setting a boundary width for the warning
and static stimulation zones of 4 m - 6 m (2 m to 3 m on each side of the wire).
The collar can be activated inside the house if the boundary wire runs along the outside
wall of the house. If this occurs, remove your pet's collar before bringing him inside,
decrease the boundary width or consider an alternate layout.
6
4A
Buried Cable
3 m
Boundary Wire
90°
4B
3 m

Publicité