WIKA PGS23.100 Mode D'emploi page 13

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. Contact protection measures
7.1. Inductive load with DC voltage
With DC voltage the contact protection can be achieved via a free-
wheeling diode, connected in parallel to the load. The polarity of the
diode must be arranged so that it closes when the operating voltage is on.
Example:
Contact protection
measure with free-
wheeling diode
7.2. Inductive load with AC voltage
With AC voltage two protection measures are possible:
Example:
Contact protec-
tion measure with
voltage-depend-
ent resistor VDR
Example:
Contact protection
measure with RC
element
WIKA operating instructions pressure gauge model PGS with reed contacts
Contact
Diode
Contact
Contact
GB
13

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

851.33

Table des Matières