Minimum water supply pressure, measured at the machine water intake during final rinsing
(flow pressure) must not be less than 150kPa (1.5bar) or more than 400Kpa (4bar) even when
other taps are opened on the same line. To prevent pressure or load drops, we recommend
that each appliance should have its own supply pipeline, that is sufficiently short and of
adequate size. It the static pressure is higher than 4bar then a pressure reducer must be
installed upstream from the supply pipeline. The supply pipeline to the machine must not have
a flow rate that is less than 15l/min. make sure that the supply water temperature is equal to
the values given in technical sheet.
To obtain good washing results, we recommend that the hardness of the supplied water being
within 7 and 12°F. If it is higher than 12°F and the appliance has no built-in water softener, we
recommend installing a water softener upstream from the fill-up solenoid valve, rated for 5-è°F
residual hardness.
Good results depend on compliance with these values. Use a flexible hose to connect the fill-
up solenoid valve to the supply water tap. The inlet hose must be in conformity with all current
National or Regional regulations.
Draining
The drain pipe must be connected to a sump or a siphon. Make sure that the drain pipelines in
the wash area are not blocked and that they afford a quick water outflow. The wall drain pipe
must withstand a minimum temperature or 70°C. This appliance has a gravity drain therefore
the outlet of dishwasher should be lower than the tank inlet. If the machine is equipped with a
pump, the position of the connection can be on the wall, but in any case it cannot be placed
higher than the height shown in Fig. E.
Electrical connections
AN EFFICIENT EARTHING SYSTEM IN ACCORDANCE WITH NORMATIVES IN FORCE
GARANTIES THE SAFETY OF THE APPLIANCE AND ITS OPERATOR. This is an essential
requirement that must be checked and if any doubt have the entire electric system checked by
the professionally qualified technician. WE CANNOT BE RESPONSIBLE FOR ANY DAMAGE
DUE TO BAD EARTHING CONNEXION. It is forbidden to use plug adapters, multi-plugs and
extensions cords. Check that the electric power supplied is in accordance with the technical
specifications (C3). The appliance must be connected to an equipotential system, in
accordance with local regulations. Connect using the clamp with the mark
located on the
back base of the appliance (C9) and using a terminal conform to a 10mm 2 sections as
mentioned in norm CEI64.8. Connection to electric mains must be done using a multipolar
magneto thermic differential switch rated with a contact gap equal to or greater than 3mm.
When selecting the type and size of the power cable, bear in mind the distance between the
appliance and the power point, the installed power indicated on the ratings label (C3) and the
2
mains voltage. The cross section of the cables must not be less than 2,5mm
. Avoid any strain
on the power cable.
Use a H07RN-Fcable if the power cable needs to be replaced connecting it to the terminal box
placed on the back of the appliance. The installation must be in conformity to CEI 67.8
(IEC364) Normative. Check high limit thermostat of heater F-B3 (if provided) by pressing the