Connection To The Battery; Configuration - Victron energy Phoenix Inverter 12/250 Manuel

Masquer les pouces Voir aussi pour Phoenix Inverter 12/250:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

3. Installation

3.1 Connection to the battery

In order to utilize the full capacity of the product, batteries with sufficient capacity and
battery cables with sufficient cross section should be used. See table:
Minimum battery capacity
Internal DC fuse
Recommended DC cable
2
cross-section (mm
)
0 – 1,5 m
1,5 – 3 m
Minimum battery capacity
Internal DC fuse
Recommended DC cable
2
cross-section (mm
)
0 – 1,5 m
1,5 -3 m
The inverters are fitted with an internal DC fuse (see table above for rating). If the DC
cable length is increased to more than 1,5m, an additional fuse or DC circuit breaker
must be inserted close to the battery.
Reverse polarity connection of the battery wires will blow the internal fuse and can
damage the inverter. The internal fuse it not replacable.
3.2 Connection to the load
Never connect the output of the inverter to another AC source, such as a household
AC wall outlet or a generator.
3.3 Remote on/off connector
A remote on/off switch can be connected to the two pole connecter. Alternatively, the
left hand contact of the connector can be switched to battery positive: useful in
automotive applications, wire it to the ignition contact.
Note that also the front switch needs to set to either On or ECO for the inverter to
start.

3.4 Configuration

The inverter is ready for use with the factory settings (see specifications), and can be
configured with a computer (VE.Direct to USB interface cable needed), Apple and
Android smartphones, tablets and other devices (VE.Direct to Bluetooth Smart dongle
needed).
12/250
24/250
38 Ah
22 Ah
60A
30A
4 mm²
2,5 mm²
6 mm²
4 mm²
12/375
24/375
66 Ah
38 Ah
80A
40A
6 mm²
4 mm²
10 mm²
6 mm²
48/250
14 Ah
25A
1,5 mm²
2,5 mm²
48/375
22 Ah
25A
2,5 mm²
4 mm²
3