Data Hold; Single-Pole Phase Test; Trip Test Of Rcd; Continuity Test (Rx) / Diode Test - Beha-Amprobe 2100-Alpha Manuel De L'utilisateur

Masquer les pouces Voir aussi pour 2100-Alpha:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40

Data Hold

When test probes are connected to an energized circuit,
pressing the push button
hold function is activated and replies with a short sound.
The LCD screen shows "the last measured value" and
"---"flashing in turns.
The hold function could deleted manually by pressing
the push button
deactivated and replies with a short sound.
The hold function is automatically deactivated after approx.
30 seconds and replies with a short sound. The voltage
tester shows, after deactivation, again the actual voltage of
the circuit under measurement in the LCD screen.
If voltages below approx. 12V AC/DC are measured data
hold is not functional. The tester shows then "---"and "- "
flashing in turns.
Data Hold
After pressing the push button
data hold function is activated and replies with a short
sound. The LCD screen shows "the last measured value"
and symbol "HOLD". The hold function can be deleted
manually by pressing the push button
hold function is now deactivated and replies with a short
sound.
Data Hold
Under data hold mode, the LCD screen will only show
the last saved measured voltage value. No auto refresh of
LCD screen reading under Data Hold mode whether the
voltage tester is connected to energized or non-energized
circuit. The LED voltage indicators
actual voltage of the circuit under measurement.

Single-pole Phase Test

The single-pole phase test works from an AC voltage
of approx. 180 VAC (2100-Alpha/2100-Beta) or approx. 100
VAC (2100-Gamma).
During the single-pole phase test to determine
external conductors, the display function may be impaired
(e.g. with insulating personal protective equipment or at
insulating locations).
W
The voltage indication in single-pole phase test is
not sufficient to assure safety. This function is not suitable
to test for absence of voltage. This always requires a two-
pole voltage test.
Connect voltage tester's test probe
The LED for single-pole phase test is ON in the display
depending on the voltage level.

Trip Test of RCD

For voltage tests in systems with RCD (earth leakage circuit
breakers) an RCD can be tripped with a 10 mA or 30mA
nominal leakage current on single phase AC 230 V power
system.
To do this, the voltage is tested between L and PE and
both pushbuttons
should trip.

Continuity Test (Rx) / Diode Test

The test circuit/object shall be de-energized before
measurement.
• Check for the absence of voltage by conducting a two-
pole voltage test on the test object.
• Connect both test probes together or press the push
button
12
• Connect both test probes to the test object. For
continuity (up to approx. 500 kΩ) the LED for
continuity Rx
(2100-Beta)
again. The data hold function is now
12
(2100-Gamma)
(2100-Beta and 2100-Gamma)
11
are pressed simultaneously. The RCD
to switch on the tester.
7
is ON and the buzzer is active.
12
for ≥ 2 seconds, the data
for ≥ 2 seconds , the
12
3
will always show the
2
8
12
again. The data
to the test object.
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2100-beta2100-gamma

Table des Matières