Voltage-free
This circuit provides three contacts for flat push-on contacts 6.3mm wide and
is not fused. The contacts act as push-on plug distributors for any distribution.
Permanent positive
This circuit (20) is permanently supplied with 12V from the PS. The output
marked with a * is being supplied when the switch (3) is actuated. This circuit
provides six contacts for flat push-on contacts 6.3mm wide and is protected
with a 15A flat push-on fuse.
Battery monitor
The circuit for the battery monitor (21) is permanently supplied with 12V by
the PS power supply. This circuit provides three contacts for flat push-on
contacts 6.3mm wide and is protected with a 7.5A flat push-on fuse.
Refrigerator
The circuit for the refrigerator is only supplied in running operation by the PS
power supply - separately and independently of the position of the main switch
(13). This circuit provides three contacts for flat push-on contacts 6.3mm wide
and is protected with a 20A flat push-on fuse.
Refrigerator
The circuit for the refrigerator is only supplied in running operation by the PS
power supply - separately and independently of the position of the main switch
(13). This circuit provides three contacts for flat push-on contacts 6.3mm wide
and is protected with a 20A flat push-on fuse.
Positive Panel
The positive panel (23) has over 30 contacts for flat push-on contacts 6.3 mm
for positive connection of users. The contacts are allocated to the previously
described circuits and flat push-on fuses.
Minus panel
The minus panel (24) has over 30 contacts for 6.3 mm flat push-on contacts for
the minus connection of users allocated to the appropriate contacts of the
positive panel.