Functions Bord Control 2005
Energised indicator and EMERGENCY ON
The battery monitor monitors Circuits 1 and 2 as well as the pump circuit and
protects the supply battery from damaging exhaustive discharge. The energised
indicator (1) turns red when the Battery 2 (supply battery) voltage falls under
10.8V and, as a result, the user circuits can no longer be supplied. By pressing
the EMERGENCY ON (1) illuminated button, the user circuits can be
switched on for a short period (approx. 2 minutes)
Vacuum WC circuit
Circuit switch (2) switches the vacuum WC ON/OFF. This circuit is
safeguarded with a 10A fuse in the junction box.
Immediate light
Circuit switch (3) switches the circuit for the immediate light ON/OFF.
User circuit
Circuit switch (4) switches the user circuit ON/OFF. This circuit is
safeguarded with a 15A fuse in the junction box.
Water pump circuit
Circuit switch (5) switches the water pump ON/OFF. This circuit is
safeguarded with a 15A fuse in the junction box.
Switch – roller blind control
The change-over switch (6) opens and closes the roller blinds.
Main switch
Through a consumer relay in the PS, the main switch (13) actuates user circuits
1 and 2, the water pump circuit and the vacuum WC ON/OFF circuit. The
effect of the supply battery (Battery 2) voltage falling under 10.8V is for the
low-voltage display (1) to illuminate and for these circuits to be shut down.