PV indicator
Off during daylight
BATT Indicator
White Slow Flashing
White Fast Flashing
Load Indicator
White Fast Flashing
Error Indicator
WhiteSolid
Error Number
25
System Status Troubleshooting
Ensure that the PV wires are correctly and tightly secured inside the
charge controller PV terminals. Use a multi-meter to make sure the
poles are correctly connected to the charge controller.
Disconnect loads, if any, and let the PV modules charge the battery bank.
Use a multi-meter to frequently check on any change in battery voltage to
see if condition improves. This should ensure a fast charge. Otherwise,
monitor the system and check to see if system improves.
Using a multimeter check the battery voltage and verify it is not
exceeding 32 volts.
The Load circuit on the controller is being shorted or overloaded. Please
ensure the device is properly connected to the controller and make sure it
does not exceed 20A (DC).
System Error. Please check LCD for Error code
E0
E1
E2
E3
E4
E5
E6
E8
E10
Troubleshoot
Troubleshoot
Troubleshoot
Troubleshoot
Error Codes
Description
No error detected
Battery over-discharged
Battery over-voltage
Battery under-voltage
Load short circuit
Load overloaded
Controller over-temperature
PV input over-current
PV over-voltage
EN