Technical Information
Interconnections
This connector carries all the input and output signals to remote
control the TV 902 Navigator.
It is a 15-pins D type connector; the available signals are detailed in
the table, the following paragraphs describe the signal characteristics
and use.
PIN N.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Signal description
START/STOP: input signal to start or stop the pump. With the
supplied cover connector the START/STOP (+) signal is connected to
the +24 Vdc pin and the START/STOP (-) signal to the GROUND pin:
in this condition the pump automati-cally starts as soon as the
controller recognises the input supply ("Plug & Pump").
INTERLOCK: input signal to control the pump rotation. With the
supplied cover connector the IN-TERLOCK (+) signal is connected to
the +24 Vdc pin and the INTERLOCK (-)signal to the GROUND pin.
248/276
SIGNAL NAME
START/STOP (+)
START/STOP (-)
INTERLOCK (+)
INTERLOCK (-)
SPEED SETTING (+)
SPEED SETTING (-)
SOFT START (+)
SOFT START (-)
+24 Vdc
RELAY CONTACT: NORMALLY OPEN
PROGRAMMABLE SET POINT
RELAY CONTACT: NORMALLY OPEN
FAULT OUTPUT
PROGRAMMABLE ANALOG SIGNAL (+)
GROUND PROGRAMMABLE ANALOG SIGNAL (-)
TV 902 Navigator User Manual / 87-900-999-01 (B)
INPUT/OUTPUT
IN
IN
IN
IN
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT