TABLE OF TECHNICAL FAULTS:
PROBLEM
Radiator is not working properly 3 dashes ( - - - ) are displayed Temperature detection sensor is faulty Contact a Service Centre
The radiator does not heat up
The radiator does not heat up
The temperature detected by the
radiator does not match with the one
detected by an ambient thermostat
The radiator does not ensure to
reach the desired temperature in
the room
Window opening detection does
not work properly
Oil leakage
The wall behind the radiator gets
dirty
Expansion noises in switching on
and/or off phase
7.

WARRANTY

The body in aluminium alloy is warranted against manufacturing defects for 5 years from date of purchase. Electric and electronic components
are warranted for 2 years from the date of purchase of the radiator. To validate your warranty, it is necessary to produce a document attesting
the date of purchase (tax receipt, invoice, sales receipt).
For the validity of the warranty, the installation must comply with regulations and laws in force and must be carried out in a
craftsmanlike manner.
Warranty does not cover components subject to standard wear or consumption, as well as damages resulting from transport or assembly.
EN-32
RADIATOR STATUS
Display OFF
Display in any mode
Radiator in comfort or
programming mode
Properly working
Properly working
The symbol
is not displayed
and the radiator is cold or
lukewarm.
The symbol
is not
displayed
The display shows the
symbol
steady on
The display shows the symbol
flashing, but no window
has been opened
Any
Any
Any
PROBABLE CAUSE
No power supply
Resistor or electronics malfunction
The radiator and the thermostat are
positioned in different places of the
room and detect different temperatures
The radiator power is insufficient to
meet the need of the room
The
radiator
position
excessively the temperature detected
in the room
The temperature set is lower than the
temperature of the room.
"Window opening" function is not
enabled.
Lowering of temperature in the rooms
has not been sudden or the position
of the radiator does not allow the
probe to correctly detect temperature
sudden changes.
The radiator is affected by cold air
drafts
Radiator connectors are not correctly
closed
During
heating,
the
carbonizes the dust present inside air
Radiator supporting brackets are not
centred and scrape on the radiator.
SOLUTION
Check the presence of mains
voltage
Contact the technical service to
have it repaired
Correct the temperature read
by the radiator as specified in
paragraph 4.5.4
Replace the radiator with a more
powerful one or add another
radiator.
affects
Relocate the radiator
Increase the temperature set.
Enable the function as per the specific
paragraph of this instruction manual
Relocate the radiator.
Relocate the radiator or, should
this not be possible, disable the
function
Contact the technical service to
have it repaired
Clean radiator at regular intervals,
radiator
use washable wall paints. Do not
smoke in the room.
Position brackets properly.