Event text
Description
U 3.3
Internal power supply outside limits
U 5.0
Internal power supply outside limits
U 15.0
Internal power supply outside limits
U PV
Input voltage from PV string too high
U-SNUBBER
Snubber voltage too high
U DC-BUS
DC bus voltage too high
U-GRID
AC grid voltage outside the threshold
values (higher or lower than setting)
F-GRID
Grid frequency outside limits (outside
settings)
IPM CURRENT
The DC content in the AC current is too
high
ENS
ENS error
ENS RAM
ENS memory error
ENS FL. CHKSM
Flash memory error after self-test
ENS EP. CHKSM
EPROM memory error after self-test
HW TRIP
Hardware trip – current too high
TEMP HIGH
Temperature in integrated power mod-
ule too high
EPRM PAR. LIM
Validity check of grid voltage and fre-
quency settings. Settings too far away
from actual grid voltage and frequency
values.
ENS COM ERR
Error in communication with ENS board Inverter
ENS impedance
Grid impedance step higher than limit
PV—CONFIG—ERR
Error detected by PV configuration test PV system
Not recorded in the event log - red LED does not flash
Event text
Description
EARTHFAULT
Current event shown in grid mode
Table 3.1: Inverter Event Log
A "permanent failure" is defined by an event having been present for more than 15 minutes.
Fault
Action in the event of a permanent fail-
origin
ure
Inverter
Service inverter
Inverter
Service inverter
Inverter
Service inverter
PV system
Request technical service from PV system
supplier
Inverter
Service inverter
Inverter
Service inverter
AC grid
In case of repeated occurrence: Request
technical service from utility
AC grid
In case of repeated occurrence: Request
technical service from utility
Inverter
Service inverter
AC grid
In case of repeated occurrence: Request
technical service from utility
Inverter
Service inverter
Inverter
Service inverter
Inverter
Service inverter
Inverter
Service inverter
Environ-
Check whether inverter is covered.
ment
Check inverter for free air flow through heat
sink. Clean heat sink.
Check that ambient temperature is within
limits.
Inverter
Request service to check inverter settings
Service inverter
AC grid
In case of repeated occurrence: Request
technical service from utility
Check the cabling of the PV panels. Two DC
inputs are wired in parallel string configura-
tion, one is not
Fault
Action in the event of a permanent fail-
origin
ure
PV system
Earth fault, check PV system for earthing to
avoid damage to PV panels. Request techni-
cal service from the PV system supplier or in-
staller.
L00410346-04