Overview
Congratulations on your purchase of the SANICON® system - the
cleanest, most sanitary, and convenient way to empty your RV
holding tank!
Read and understand the warnings listed in this docu-
!
WARNING
ment before you operate or service this system. If you do
ATTENTION
not obey these warnings there is a risk of property loss,
injury, or electrocution. Do not make any changes to this
unit as this could result in property damage, injury, or
electrocution.
Thetford Corporation accepts no responsibility or liability for
damage to equipment, injury, or death that may result from the
system's improper installation, service, or operation.
Thetford Corporation recommends that plumbing and electrical
work be performed by a licensed tradesperson. Local permit and
code compliance is required.
Cautions and Warnings
Read and understand the warnings and cautions listed in this
document before you operate, or service this unit.
Wear appropriate personal protective equipment when
!
WARNING
using the SANICON® system.
ATTENTION
Do not make any changes to this unit, as this
AVISO
AVIS
!
NOTICE
CAUTION
could result in property damage or injury.
Flush only organic human waste and toilet
tissue. Do not fl ush non-dissolving articles such as
feminine hygiene products, paper towels, or moist tow-
elettes, as this will damage the macerator and will void
your warranty.
To avoid pump failure, if you are using an accessory
garden hose on the end of the nozzle, make sure that the
inner diameter of the hose is 3/4 in. (1.9 cm) or greater.
The pump is suitable for indoor and outdoor use.
NOTICE
Inspect pump connection to the RV annually. Make sure
there are no cracks in the rubber coupling and the mount-
ing hardware is secure. Replace when necessary.
Thermal Cut-Off Switch
Because SANICON® Turbo pumps are designed for intermittent
duty, the pump contains a thermal cut-off switch for your safety.
Typical run time is 15-20 minutes of operation before the thermal
shut-off switch turns the pump off. After 20 minutes, the thermal
cut-off switch will reset and allow the pump to run again.
■ If the pump is run immediately after a thermal reset, it will run
for approximately five - eight minutes.
■ If allowed to cool for several hours it will run the full 20 min-
utes..
Questions?
If you have any questions or need assistance, please contact
Customer Service at 1-800-543-1219, available Monday through
Friday 8 a.m. to 6 p.m., Eastern Standard Time.
97539 Rev. B (07/10/2017)

Operation

Pump Performance
Performance varies with hose size and length:
& Length
SANICON
®
hose 1.5" x 21'
SANICON
®
hose 1.5" x 21'
SANICON
®
hose 1.5" x 21' w/
100' 3/4" garden hose
SANICON
®
hose 1.5" x 21' w/
100' 3/4" garden hose
®
SANICON
hose 1.5" x 21' w/ 50'
3/4" garden hose
Thermal cut-off will occur after 20 minutes. Refer to
i
"Thermal Cut-Off Switch" discussion.
Attach to Dump Station
Refer to the Fig. 1.
1. Open discharge hose storage compartment (
(
E
) and universal nozzle (
from coach.
NOTICE
2. Unscrew large nozzle cap (
3. Attach universal nozzle (
Empty Black Water Tank
Refer to the Fig. 1.
1. Be sure universal nozzle (
station! Refer to "Attach to Dump Station" procedure.
NOTICE
2. Open black water tank gate valve (
3. Turn pump on.
4. Do not leave unit unattended.
NOTICE
5. Turn pump off.
6. Close black water tank gate valve (
2
Hose
Height
9'
0
9'
0
0
F
) with caps; do not disconnect
Remove large nozzle cap (
G
).
G
F
) to dump station.
F
) is securely attached to dump
TIP For Cleaner Storage: Emptying the black water tank
fi rst, allows gray water to cleanse the system.
L
).
TIP: The hose expands as fl uid moves to dump
station and contracts when tank is empty.
L
).
SANICON
Flow
Minutes to
Rate
Empty 100
(gal/
Gallons
min)
11.1
9
18.7
5
0.7
143
i
3.7
27
i
6.2
16
I
); pull out hose
) for full hose extension.
®
Turbo - Model 500