Technical features (see type plate)
Corresponds to the standard EN 60730-1,
-2-9
Batteries thermostat: 2 x 1.5 V, type LR03
or AAA
Radio frequency: 868 MHz
Performance data radio receiver
Nominal voltage
Cable cross section
recommended wire
end ferrules
Maximum
switching capacity
Resilience of the
contact
Power consumption
in the stand-by
mode
Insulation type wall
outlet
Protection type
wall outlet
Protective areas in rooms with bath
or shower facilities (for installation
examples, see Fig. A)
According to national installation stan-
dards (in Germany DIN VDE 0100-701)
electrical equipment may only be installed
in specific areas in rooms with bathtubs or
shower facilities.
Electrical equipment is permitted in the
rooms referred to above if it is protected by
a residual current protective device (RCD)
(in Germany according to DIN EN 61008-1
(VDE 0664-10)).
Sockets may only be installed outside safety
areas.
Note: the manufacturer does not approve
the installation of products in protective
area 1.
Install the following products only in pro-
tective area 2 or outside the protective are-
as:
Radiator with heating element (DIN
55900 note "coatings for radiators".)
Thermostat WFS
Wall outlet IPX4 with radio receiver
8
230 V AC
1 x 1.5 mm²
L = 10 mm according to
DIN 46228
1800 W
8 A / 250 V ~ at cos φ = 1
or
2 A / 250 V ~ at cos φ = 0,6
approximately 0.9 W
Protection class I or
protection class II
IPX4 after proper
installation
Installation
Preparatory activities
Ensure that a outlet socket (230 V, fuse B16
A) is there within the reach of the cable of
the heating element.
To install a radio receiver, it is advisable to
use a outlet socket with an installation depth
≥ 40 mm and diameter of 68 mm.
The outlet socket must be freely accessible and
may not be in the projection surface of the ra-
diator.
Install radiator and heating element.
Install thermostat and radio receiver/wall
outlet
Check the delivery for completeness and
damages (see Fig. B).
Install thermostat according to Fig. C1 / C2 .
Install radio receiver and wall outlet accor-
ding to Fig. D1–D5.
Electrical connection
The device may only be connected by an elec-
trical specialist.
D5: setup electrical connection according to
the diagram Fig. E1 (protection class I) or E2
(protection class II).
Designation of the wires:
L' = phase heating element (brown)
L = phase network (brown)
N = neutral heating element (blue)
N = neutral network (blue)
PE = protective conductor (green / yel-
low, only for protection class I)
Setup radio communication
D6: press the button on the thermostat 2 x
–> LEDs (6) blink white
D7: press the button on the radio receiver 1 x
–> LED (7) blinks green
If the LED (7) lights continuously for appro-
ximately 5 seconds, the learning procedure
has failed. Restart the learning procedure.
D8: press the button on the thermostat 1 x
–> LEDs (6 and 7) are off
Radio communication was setup successful-
ly. The learning procedure remains saved
even after interrupting the power supply.
D9: install splash protection cover
The LED (8) displays the operating mode of the
heating element.