7. Troubleshooting

Display
Fault
E03E
Overheated coil
E05E
Temperature increase of less
than 1 °C (1.8 °F) every 1
minute (or every 2 minutes)
E06E
Temperature probe not
connected (or defective) or
excessive temperature drop
E10E
Electronics communication
problem
E11E
Electronics communication
problem
E12E
Electronics communication
problem
14
Action
Wait until the induction coil cools. Switch
the heater OFF and then back ON
Check the temperature probe
connection. If the connection is OK,
select the 2 minutes interval as
described in section 6 or operate the
heater in TIME MODE
Check the temperature probe
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair
Switch the heater OFF and then back
ON. If problem remains return the TIH
to SKF for repair
SKF TIH L