Extension Cords - Haussmann HAUS 968-12 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

When using the appliance at a distance where an extension cord becomes necessary, a 3-conductor
grounding cord of adequate size must be used for safety, and to prevent loss of power and overheating.
Use the table below to determine A.W.G. wire size required. To determine ampere rating of your vacuum,
refer to nameplate located on rear of motor cover. Before using appliance, inspect power cord for loose
or exposed wires and damaged insulation. Make any needed repairs or replacements before using
your appliance. Use only three-wire outdoor extension cords which have three-prong grounding-type
plugs and three-pole receptacles which accept the extension cord's plug. When vacuuming liquids, be
sure the extension cord connection does not come in contact with the liquid.
NOTE: STATIC SHOCKS ARE COMMON IN DRY AREAS OR WHEN THE RELATIVE HUMIDITY OF THE AIR IS
LOW. THIS IS ONLY TEMPORARY AND DOES NOT AFFECT THE USE OF THE APPLIANCE. TO REDUCE THE
FREQUENCY OF STATIC SHOCKS IN YOUR HOME, THE BEST REMEDY IS TO ADD MOISTURE TO THE AIR
WITH A CONSOLE OR INSTALLED HUMIDIFIER.
UNPACkING AND SET-UP
WARNING
– ALWAYS DISCONNECT THE PLUG FROM THE
WALL OUTLET BEFORE REMOVING THE TANk COVER.
1. Pull lid latches in an outward motion and remove tank cover. Remove any accessories,
which may have been shipped in the tank.
2. Attach caster system following the instructions and illustrations below.
3. Before replacing tank cover ensure you have the proper filters installed for your cleaning
operation.
a. For dry pick-up refer to Dry Pick-Up Operation.
b. For wet pick-up refer to Wet Pick-Up Operation.
c. When using the pump operation feature refer to Pump Operation.
4. Be sure inlet deflector is positioned correctly.
a. For dry pick-up the opening must be facing down. (See Installing the Cartridge
Filter)
b. For wet pick-up and pump operation the opening must be facing up. (See Wet Pick-
Up Operation)
5. Replace tank cover and apply pressure with thumbs to each latch until it snaps tightly in
place. Make sure both lid latches are clamped securely.
6. Insert long machine hose end with locking-nut into inlet of tank and tighten. Do not over-
tighten.
7. Attach ergonomic elbow grip to accessory end
of hose for a more comfortable hand grip while
vacuuming. Twist slightly to tighten the connection
(Figure 1).
8. Attach the extension wands to the ergonomic elbow
grip. Twist slightly to tighten the connection (Figure 1).
9. Attach one of the cleaning accessories (depending on your cleaning requirements) to the
extension wands. Twist slightly to tighten the connection (Figure 1).
10. Plug the cord into the wall outlet. Your cleaner is ready for use. I = On, O = Off
NOTE: MANY MORE USEFUL TOOLS ARE AVAILABLE AT YOUR LOCAL RONA STORE.
CASTER SYSTEM ASSEMBLY
You will find four casters (Figure 2), two caster feet (Figure 3), rear caster dolly/tool holder
(Figure 4), and four screws with your wet/dry vacuum. Assemble as follows:
2
1. With cord disconnected from receptacle and tank cover removed, turn tank upside down so
that the bottom is facing up.
2. Take rear caster dolly and place into slots (on rear of tank, opposite of drain) and secure with
screws provided (Figure 5).
3. If flat washers are included in hardware package place flat washer over stem of caster before
installing casters into feet. NOTE : Flat washers are not required with all units.
4. Insert casters into bottom of rear caster dolly by placing stem of caster into holes provided.
Apply pressure and twisting motion until casters snap into place (Figure 6).
5. With tank drain facing you, take caster foot marked with the letter A (Figure 7) and place
in slot on left side of tank also marked with the letter A. Secure with screw
provided (Figure 8).
6. Take caster foot marked with the letter B (Figure 9) and place in slot on
right side of tank also marked with the letter B. Secure with screw provided
(Figure 10).
7. Insert casters into feet by placing stem
of casters into holes provided. Apply
pressure and twisting motion until casters
snap into place (Figure 11).
8. Return tank to upright position.

EXTENSION CORDS

1
3
4
6
7
A
9
10
A
B
A
Ampere Rating
More
Than
INSTALLING FOAM SLEEVE AND REUSABLE
(Not standard with all models)
WARNING
WALL OUTLET BEFORE REMOVING THE TANk COVER.
1. The foam sleeve and reusable dry filter may be used to pick up dust and dry material; you
must install both to insure proper filtration. If the vacuum has been used to pick-up liquids,
the foam sleeve must be cleaned and dried before installing for dry pick-up. (See Wet Pick-Up
Operation on how to clean foam sleeve).
2. With tank cover in an upside down position, slide foam sleeve down over lid cage pulling until
foam sleeve completely covers lid cage (Figure 12). Foam sleeve must be positioned on the
OUTSIDE of groove around lid cage for the reusable dry filter to fit properly (Figure 13, 14).
3. Center the reusable dry filter on bottom of lid cage (Figure 15), slide mounting ring over filter
until ring is positioned against the top of the lid cage (Figure 16).
NOTE: ENSURE THAT THE MOUNTING RING IS COMPLETELY SECURE AND IN POSITION BY
PRESSING DOWN FIRMLY AROUND THE RING IN SEVERAL PLACES. BE SURE THE REUSABLE
DRY DISC FILTER COMPLETELY COVERS THE FOAM SLEEVE. CHECK TO ENSURE THAT ALL
EDGES OF THE REUSABLE DRY FILTER ARE SECURE UNDER THE MOUNTING RING.
4. Be sure the opening of the inlet deflector is facing the tank bottom. If it is not, remove inlet
deflector from the deflector guide sliding in an upward motion. NOTE: Hose must be removed
before inlet deflector can be taken out. Reinstall being sure the opening of the inlet deflector
is facing the tank bottom (Figure 17).
5. To clean the reusable dry filter
a.
Remove mounting ring and filter from lid cage (Figure 18).
b.
Shake off excess dirt and dust or (depending on the condition of the filter) rinse with
water. DO NOT MACHINE WASH OR DRY.
c.
To clean foam sleeve refer to Wet Pick-Up Operation in this manual.
d.
Allow filters to dry completely before reinstalling.
CAUTION
IMPORTANT: BEFORE INSTALLING FILTER BE SURE THAT FOAM SLEEVE IS OUTSIDE OF GROOVE
AROUND LID CAGE (Figure 13, 14).
INSTALLING THE CARTRIDGE FILTER
(Not standard with all models)
NOTE: If foam sleeve is installed, it does not need to be removed before installing the cartridge
5
filter. Foam sleeve must be positioned on the INSIDE of groove around lid cage for the cartridge
filter to fit properly.
Dry Pick-Up:
NOTE: If the filter has been used for wet pick-up, it must be cleaned and dried before using
for dry pick-up.
1. The cartridge filter can be used for most general dry pick-up.
8
2. Be sure the opening of the inlet deflector is facing the tank bottom. If it is not, remove
inlet deflector from the deflector guide sliding in an upward motion. NOTE: Hose must be
removed before inlet deflector can be taken out. Reinstall being sure the opening of the inlet
deflector is facing the tank bottom (Figure 19).
A
3. With tank cover in an upside down position, slide cartridge filter over lid cage, pushing until
11
the filter seals against the cover (Figure 20).
4. Place filter retainer into top of the cartridge filter, hold the tank cover with one hand while
turning the handle on the filter retainer clockwise to tighten and lock into place (Figure 21
& 22).
B
Total length of cord in feet
Volts
25
50
120V
Not More
Than
18
16
0
-
6
18
16
6
- 10
16
16
10
-
12
12
-
16
14
12
DRY PICk-UP
DRY FILTER
– ALWAYS DISCONNECT THE PLUG FROM THE
– kEEP FILTERS CLEAN
14
12
13
17
16
100
150
AWG
16
14
14
12
14
12
Not recommended
15
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

05915036

Table des Matières