TIPS FOR ENERGY SAVING

DO NOT:
Block the air intake and outlet of the unit.
l
If they are obstructed, the unit will not work well, and
may be damaged.
Let direct sunlight into the room. Use sunshades, blind
l
or curtain.
DO:
Always try to keep the air filter clean. A clogged filter
l
will impair the performance of the unit.
To prevent conditioned air from escaping, keep windows,
l
doors and any other openings closed.
TROUBLESHOOTING
The use of portable telephones near the air-conditioner
may cause disturbance to its normal operation and must
be avoided. In case abnormal operation is noticed,
(OPERATION lamp lights but outdoor unit will not run) to
restore normal operation turn-off electric supply for 60
seconds at least, by disconnecting the main switch or
the wall plug, then start again the air-conditioner.
The blinking OPERATION lamp, together with the stop of
the air conditioner for a short time are due to the exceeding
condensate drainage.
If the OPERATION lamp goes on blinking and the air
conditioner definitely stops means that the condensate
pump is not working or that the condensate drain pipe in
the flexible connection pipe is obstructed; in this case
contact the AFTER SALE SERVICE.
In case of emergency the air conditioner can work by
draining the condensate from the back little pipe into a
rather short container: extract the little pipe and remove
the cap.
If your air conditioner does not work properly, first check
the following points before requesting service.
If it still does not work properly, contact your dealer or
service center.
AUTO-DIAGNOSIS
LEDS
STANDBY OPERATION
F
F
O
F
F
O
F
l
F
O
F
l
O
F
O = LED OFF
= LED ON
l
F = Flashing LED
TIMER
O
Defective indoor air sensor
F
Defective indoor air coil sensor
O
Defective compressor discharge temperature sensor
O
Malfuctioning of electronic PCB (current protection)
Malfuctioning of electronic PCB (temperature protection) Contact service centre
l
Malfuctioning of PFC (power factor correction system)
l
O
Malfunctioning of the condensate drainage system
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service center.
3. Consult your electrician or dealer.
4. Press the button again.
5. Replace batteries.
Trouble: Compressor runs but soon stops.
Possible cause:
1. Obstruction in front of condenser coil.
Remedy:
1. Remove obstruction.
Trouble: Poor cooling performance.
Possible cause:
1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high.
Remedy:
1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower.
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. Any plastic parts may expand or shrink due to a sudden
temperature change. In this event, a clicking sound may
occur.
Remedy:
1. This is normal, and the sound will disappear when an
even temperature is settled.
NOTE
The fixed OPERATION lamp and the blinking of TIMER and
STANDBY lamps, indicates that the operating mode selected
(
) is not compatible with the unit. If this happen the air
conditioner does not operate until the correct mode is
selected.
POSSIBLE CAUSE
12
REMEDY
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre
Contact service centre